Amprobe 38XR-A User Manual page 32

Professional digital multimeter
Hide thumbs Also See for 38XR-A:
Table of Contents

Advertisement

Available languages

Available languages

10A input
Burden voltage
AC CURRENT true rms (AC+DC) (45 Hz to 1 kHz)
Ranges
Resolution
Accuracy
Peak Hold
accuracy
Crest Factor
Input protection
10A input
Burden voltage
10 A for 4 minutes maximum followed
by a 12 minute cooling period
μA Range: 1 mV/ 1 μA
mA Range: 1 mV/ 1 mA
10A: 30 mV/ 1 A
100 uA, 1000 μA, 10 mA, 100 mA,
400 mA, 10A (auto/manual ranging)
0.1 μA
True rms/±(1.5 % rdg + 20 dgts)
on 100 μA to 100 mA ranges
True rms/±(2.0 % rdg + 10 dgts)
on 400mA range
True rms/±(2.5 % rdg + 20 dgts)
on 10A range
±(3.0 % + 200 dgts)
AC coupled true RMS specified
from 5 % to 100 % of range
AC+DC/±(2.0 % rdg + 20 dgts)
on 100 μA to 400 mA ranges
AC+DC/±(3.0 % rdg + 20 dgts)
on 10A range
AC coupled true RMS specified
from 10 % to 100 % of range
≤ 3
0.5A/1000V fast blow ceramic fuse
6.3×32mm on μA/mA input
10A/1000V fast blow ceramic fuse
10×38mm on 10A input
10 A for 4 minutes maximum
followed by a 12 minute cooling
period
See DC Current
26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents