Haier AB25S2SC1FA Service Manual page 126

R32
Table of Contents

Advertisement

2.2 Dip switch setting
Outdoor main PCB 0151800075B dip switch setting SW5
SW5-1
SW5-2
SW5-3
OFF
OFF
---
ON
OFF
---
ON
ON
---
---
---
OFF
---
---
ON
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Small service PCB:0151800076A dip switch setting SW1
SW1-1
SW1-2
SW1-3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
SW7: Except the SW7-3, all the other dip switch setting is OFF
SW7-3
ON
OFF
SW5-4
SW5-5
SW5-6
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
---
---
---
---
---
---
---
---
---
---
---
---
SW1-4
OFF
State when out of factory
Compulsory heating: 50Hz, outdoor motor 5-class, standard open angle 200,
OFF
the others are normal
Compulsory cooling: 60Hz, outdoor motor 7-class, standard open angle 200,
OFF
the others are normal
OFF
Rated operation
ON
Time defrost valid
ON
Detection for wrong wiring
Description
Mute available
Mute unavailable
SW5-7
SW5-8
---
---
---
---
---
---
---
---
---
---
Max Running Current:15A(default)
---
---
---
---
---
---
---
---
OFF
---
Temperature correction invalid(default)
ON
---
Temperature correction valid
---
OFF
Defrosting temperature:8°C(default)
---
ON
Defrosting temperature:6°C
Description
124
Description
Heat pump(default)
Cooling only
Heating only
Adjust by machine types
3U52S2SG1FA
3U68S2SG1FA
4U70S2SH1FA
4U85S2SH1FA