5.9 Networking Configuration Menu

The V2040N stands out for networking capability that permits a
maximum of 64 separate V2040 systems (sites) to communicate
with each other in a network.
MAIN SELECTION
1 SYSTEM
2 MONITOR
3 CAMERA
4 PORTS
5 ACCESS
6 PRIORITY
7 SATELLITE
Function
Enables or disables the System Reset (see Section 4.1) ability for the user/keyboard.
Options
Y = yes (to enable the user/keyboard to reset the system);
N = no (to prevent the user/keyboard from resetting the system).
Use the ACK key to select.
Function
Decides whether the Camera Lockout ability (see Section 4.6) is allowed for the user/keyboard.
Options
Y = yes (to give the user/keyboard the Camera Lockout ability);
N = no (to disable the Camera Lockout ability for the user/keyboard).
Use the ACK key to select.
Function
Defines the Keyboard-to-Camera View/Control ability for the user/keyboard.
Options
UTILIZE V/C ACCESS = KEYBOARD/CAMERA VIEW (see Section 5.7.3) and
KEYBOARD/CAMERA CTRL setup are valid (see Section 5.7.4).
OVERRIDE V/C CONTROL = to restrict the user/keyboard to view and control all the
system cameras.
Use the ACK key to select.
Function
Enables or Disables the Menu Access ability for the user/keyboard.
Options
Y = yes (to give the user/keyboard the Menu Access ability);
N = no (to disable the Menu Access ability for the user/keyboard).
Use the ACK key to select.
Function
Determines whether the user/keyboard is allowed to change system parameters.
Note
F
To use this function, Item
Options
Y = yes (to give the user/keyboard the ability to change system parameters);
N = no (to prevent the user/keyboard from changing system parameters).
Use the ACK key to select.
SATELLITE CONFIGURATION

1 LOCAL SITE NUMBER

2 VIDEO TRUNK ASSIGNMENT
3 REMOTE SITE IP ADDRESS
RETURN MAIN
must be enabled first.
5.9.1 Local Site Number
Each site in a network must be assigned a separate Site Number.
This Site Number is required for addressing purpose when
commands and data are transmitted via the TCP/IP interfaces
between sites. The Site Number menu allows assigning a Site
Number and Priority Level to the Local Site.
Each Site must be setup locally for its Site Number.
SATELLITE CONFIGURATION
1 LOCAL SITE NUMBER
2 VIDEO TRUNK ASSIGNMENT
3 REMOTE SITE IP ADDRESS
RETURN MAIN
LOCAL SITE NUMBER
A
LOCAL SITE NUMBER : 001
IP ADDR : 192.168.000.000
B
MASK
: 255.255.255.000
C
GATE
: 192.168.000.000
D
PRIORITY LEVEL : 8