Infinova V2040 Installation & Operation Instructions page 42

V2040 series. video matrix switching system
Table of Contents

Advertisement

Item
F
CN
Item
G
ACN
Item
H
SITE
36
Function
Connect Next (see the following examples for details).
Options
N = no (no Connect Next function is desired).
Y = yes (to call the camera in the next CAM entry simultaneously to the next contiguous
monitor).
ACN
CAM
DWL
0001
0001
05
0002
0002
00
The sample entries shown above indicate that when Alarm Contact 1 (ACN 0001) is
alarmed, Camera 1 (CAM 0001) will be automatically displayed on the monitor associated
with Alarm Contact 1 (see Section 5.7.6), and Camera 2 (CAM 0002) will be
simultaneously displayed on the next contiguous monitor.
Note: The dwell time of CAM 0002 is defined as "00" since it is controlled by the previous
entry, CAM 0001.
The monitor arming types can be BSI, BSA, BSM, BHI, BHA, BHM when CN is set to 'Y'
S = salvo (to call up a system salvo).
Note: At this point, the associated CAM entry indicates the salvo number.
ACN
CAM
DWL
0003
0001
10
The sample entries shown above indicate that when Alarm Contact 3 (ACN 0003) is
alarmed, System Salvo 1 (CAM 0001) will be automatically called up. The monitor
associated with Alarm Contact 1 (see Section 5.7.6) will become the first monitor for the
called salvo.
Note: The monitor arming types can be BSI, BSA, BSM, BHI, BHA, BHM when CN is set
to 'S'
W = wired group (to activate all the ACN entries in a contiguous "wired group").
Note: To define a "wired group", the last CN entry of the group must be set to "N" or "S"
while all the previous CN entries are set as "W".
ACN
CAM
DWL
0005
0005
02
0006
0006
02
0007
0007
02
The sample entries shown above have defined a "wired group" of three ACNs. If any alarm
contact in the group is alarmed, all the three associated cameras will be simultaneously
called to a contiguous group of monitors.
W< = wired group for group clear. Its only difference from W is the clearance method:
clearing the alarm on any of the alarmed monitors will clear all alarmed videos in the group,
while a W option requires manual clearance on each individual monitor.
Note: The other three options, N<, Y<and S<, are factory reserved.
The alarms on the monitor must be cleared manually one by one when CN is set to 'W<'and
the arming type is SSM, SHM, BSM, BHM or DHM.
Function
Alarm Contact Number, each indicating an alarm contact in the local system.
Note
Since each ACN entry is a unique one, a camera can be called as many times as required, with
different dwell times, presets, etc.
Function
Selects a remote site to associate a camera in the site.
To select a desired remote site,
1)
Enter the site number on the keypad.
2)
Press the ACK key to select.
Note
When a valid site number is entered in the SITE entry, the camera number in the CAM entry (
will indicate the corresponding camera in the selected remote site.
PRE
AUX
CN
001
1-ON
Y
001
0-
N
PRE
AUX
CN
000
0-
S
PRE
AUX
CN
001
1-ON
W
001
0-
W
001
0-
N