Installing and Connecting the Outdoor Unit Drain Hose

When using the air conditioner in the heating mode, ice may
accumulate. During de-icing, the condensed water must be drained
off safely. Consequently, you must install a drain hose on the outdoor
unit, following the instructions below.
1
Insert the drain plug into the drain hole on the underside of the outdoor
unit.
2
Connect the drain hose to the drain plug.
3
Ensure that the drained water runs off correctly and safely.

Fixing the Unit in Position

The outdoor unit must be installed on a rigid and stable base to avoid any increase
in the noise level and vibration, particularly if the outdoor unit is to be installed close
to a neighbour. If it is to be installed in a location exposed to strong winds or at a
height, the unit must be fixed to an appropriate support (wall or ground).
1
Position the outdoor unit so that the air flow is directed towards the
outside, as indicated by the arrows on the top of the unit.
2
Attach the outdoor unit to the appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.
Certainly fix up its rubber leg, in order to prevent its vibration and noise.
I
O
NSTALLING THE
Drain hole
Unit : mm(inch)
660(26)
Rubber leg
U
UTDOOR
NIT