1. SAFE TY RULES
This meter is designed for indoor use at temperatures between 0°C to 40°C and
•
altitudes up to 2,000m.
• To ensure that the meter is used safely, follow all safety and operating instructions in
this operation manual. If the meter is not used as described in this operation manual,
the safety features of this meter might be impaired.
• Do not use the meter if the meter or test leads look damaged ,or if you suspect that
the meter is not operating properly.
• When using the instrument, keep your fi ngers behind the fi nger guards on the plastic
casing and probes.
• Disconnect the live test lead before disconnecting the common test lead.
• Make sure power is off before cutting, desoldering, or breaking the circuit wires. Small
amounts of current can be dangerous.
• Do not apply more than 600 VDC or 600V AC rms between a terminal and ground.
• To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC
rms. Such voltages pose a shock hazard.
• Never make measurements with the battery cover off.
• To avoid electrical shock or damage to the meter, do not exceed the input limits.
2. INTERNATIONAL SYMBOLS
Important information
see manual
AC
DC
3. TECHNICAL SPECIFICATIONS
3.1 General Specifi cations
Display:
3 3/4 digit LCD with decimal point and
33 segments bargraph display.
Polarity:
Automatic, (-) negative polarity indication
Zero adjustment:
Automatic
Sample rate:
0.5 Sec.
Over range indication:
Symbol
Power:
2 x 1.5 V battery, type AA, UM3 or equiv.
Power saving:
Automatic power off
Battery life:
Approx. 50 hours. (w/ alkaline batteries)
Dimension:
6.34 x 3 x 2" (HxWxD).
Weight:
Approx. 11.4 Oz. (including batteries)..
Accesories:
User's Manual,Test Leads,Protective,
Holster, Soft Pouch and 2 x 1.5 Volt
alkaline batteries
3.2 Electrical Specifi cations
•
Accuracies are ±(% of reading + number of least signifi cant
digits) at 23°C ±5°C, less than 75% RH.
Function
Range
Accuracy
320 mV
0.8%+2
DC Voltage
3.2V, 32V,
1.2%+2
320V, 600V
3.2V, 32V,
AC Voltage
1.2%+5
320V, 600V
320A,
3200A,
1.5%+2
32mA,320mA
DC Current
10A
2.5%+2
320A,
3200A,
1.5%+5
32mA,320mA
AC Current
10A
2.5%+5
Dangerous Voltages
Continuity
Ground
Double Insulation
is displayed
"
"
Input
Overload
Remarks
Impedance
Protection
2 M
-
600 Vp-p
2 M
50~400Hz
600 Vp-p
Fuse
protection
< 163 mV Voltage Drop
10 A - 250V,
10A max. for <10 Sec
10A max.
10 sec.
Fuse
protection
< 163 mV Voltage Drop
10 A - 250V,
10A max. for <10 Sec
10 A max
10 sec.
Function
Range
Accuracy
320, 3.2K,
32k,320k
1.2%+5
Resistance
3.2M
32M
3.5%+5
Continuity
Buzzer sounds when <18
Displays forward diode Volt-
Diode Test
age drop (Vf)
4. OPERATION
4.1 Instrument Description
1) Case
2) Display
3) Hold button
4) Function switch
5) Input and common
connectors
6) Alterate function button
7) Range button
4.2 LCD Display Description
Beeper enable
Digital Readout
DC
Data Hold
H
AC
Diode test
.........
0
enable
Analog bar graph
4.3 Measurement Procedures
CAUTION: Maximum Input Voltage is 600Vrms,do not exceed
this rating to avoid personal injuries or damage to
the instrument. The range FUNCTION/RANGE
switch should be set to the range you want to test
before the operation.
CAUTION: Always ensure that the correct terminals are used for
the type of measurement to be made. Avoid making
connections to "live" circuits whenever possible.
When making current measurements ensure that
the circuit is not "live" before opening it in order to
connect the test leads.
8017
CT
Remarks
Max. Testing Voltage:
< 1.5 V
Test Voltage: 1.2 V Max.
Test Current < 0.6mA
1
GTC
CT8017
H
2
.........
.........
.........
0
1
2
HOLD
3
Ω
μ
A
V
mA
V
OFF
4
AC DC
AUTO OFF
AUTO
SELECTION
CAT II
max 10A
MAX 600V
fused
400mA fused
10A
COM
5
max
600V
Manual range
enable
MAN
Measurement
mV
Mk
units
-
+
Low battery
.........
.........
..
1
2
3
Overload
Protection
250 Vp-p
250 Vp-p
250 Vrms
250 Vrms
MAN
mV
Mk
-
+
..
3
7
RANGE
6
10A
Ω
V
mA