Specifications; General Specifications; Range Specifications - Extech Instruments 380460 User Manual

Precision milliohm meters
Table of Contents

Advertisement

Specifications

General Specifications

Circuit
Display
Measurement terminals
Measurement ranges
Zero Adjust
Sampling Time
Over range indication
Operating Temperature
Operating Humidity
Power Supply
Power Consumption
Weight
Dimensions
Accessories

Range Specifications

Range
200 m
2 
20 
200 
2000 
Note: Specifications tested using RF Field Strength <3V/m and frequency <30MHz
All rights reserved including the right of reproduction in whole or in part in any form.
www.ponpe.com
Custom one-chip LSI microprocessor circuit
18 mm (0.7") LCD with 2000 display counts
4-Terminal Kelvin type
Five (5) ranges (200m, 2, 20, 200, 2000 ohms)
±50 count adjustment
Approximately 0.4 seconds
Indication of "1 "
0 °C to 50 °C (32 °F to 122 °F)
80% Relative Humidity max.
110V (380460) or 220V (380462) ±15%, 50/60Hz
Less than 2 VA
694g (1.53 lbs.)
167 x 122 x 85 mm (6.6 x 4.8 x 3.4") with cover
Power Cable and 4-wire Kelvin clip leads(380465)
Test
Resolution
Current
100mA
0.1m
10mA
1m
10mA
10m
0.1 
1mA
1 
1mA
Copyright © 2013-2015 FLIR Systems, Inc.
ISO‐9001 Certified 
www.extech.com
Accuracy
± 0.75% + 4 digits
± 0.75% + 2 digits
± 0.75% + 2 digits
± 0.75% + 2 digits
± 0.75% + 2 digits
5
380460/380462-en-GB_v2.5 8/15
Open Circuit
Voltage
4.4V
3.6V
3.6V
3.5V
3.5V
contact:
sale@ponpe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 380460 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

380462

Table of Contents