autostarting time automatically on again. In case the short circuit is
still there after autostarting, the booster switches off immediately.
This procedure is repeated five times, followed by a one minute
break. à Eliminate the short circuit.
The watchdog function is not active after switching on the booster
although it has been set active.
Possible reason: The watchdog function will only be activated after a
switching command has been sent to the assigned points address.
à Enter a switching command for the points address.
After a points switching command the booster has been switched off,
the LED flashes yellow.
Possible reason: The points address in question has been assigned to
the function "switching off by a DCC switching command". à Set
the function inactive or avoid to use the points address in question.
After a points switching command the booster has been switched off,
the LED flashes red.
Possible reason: The points address in question has been assigned to
the watchdog function, but there is no PC Control with this function
in use. à Set the function inactive or avoid to use the points
address in question.