Settings - tams elektronik B-4 User Manual

Table of Contents

Advertisement

Booster B-4

7. Settings

The booster B-4 can be set to individual requirements by programming
on main (POM) or by inserting short-circuit terminations (jumpers).
Track voltage
Autostarting time
after a short circuit
Max. track current
(interrupting
current after a short
circuit)
RailCom
Switching off with a
DCC points
switching command
Watchdog
Limiting value for
short circuit
warning
Autostarting time
after 5 short circuits
Possible settings
10 – 24 V, to be set
in 1 V-steps
4 – 10 Sek., to be
set in 1 sec.-steps
2 – 5 A,
to be set in
1 A-steps
active or inactive
active or inactive /
assigning the points
address
active or inactive /
assigning the points
address
0,2 – 1 A,
to be set in
0,2 A-steps
10 – 100 sec.
Manu-
Setting
facturers
with
settings
jumpers
18 V
yes,
16 – 22 V
4 sec.
4 sec.or
10 sec.
5 A
yes
active
no
inactive
no
inactive
no
0 A
no
inactive
60 sec.
no