Wire-Free Contact Sensor
User's manual
Replacing a sensor
Check the sensor before use
If you have purchased this new VC7002A
accessory sensor to replace an old sensor,
1. Separate the sensor unit from the magnet
follow the instructions to deregister your
unit.
old sensor. VC7151-102A/VC7151-202A/
VC7151-302A telephone system can support
up to 30 sensors.
To replace a sensor, deregister the registered
sensor first, and then register this new
sensor to the telephone base.
To deregister a sensor on VC7151-102A/
VC7151-202A/VC7151-302A series:
1. Press MENU when the phone is not in use.
2. Enter the code *33734# to access the
DEREGISTER menu.
3. Scroll to Single sensor, and then press
•
You will receive alerts at your telephone
SELECT.
base. Refer to the Installation guide or
4. Scroll to the sensor you want to
User's manual of your telephone base
deregister, and then press SELECT.
for the sensor alerts.
5. Press
YES
to confirm the deregistration.
2. Combine the sensor unit with the magnet
The telephone base shows Contact X is
unit.
deregistered and you hear a beep when the
deregistration process completes.
Congratulations
VC7002A
on purchasing your new VTech product.
Before using this product, please read
Accessory
Important safety instructions.
This manual has instructions on how to
for use with
set up and register your new sensor. For
instructions on sensor settings, see the
VC7151-102A/
user's manual that came with your telephone
VC7151-202A/
base.
VC7151-302A
Test the sensor signal strength
You can mount the Contact Sensor on a
door, window, drawer, cupboard, jewelry box,
or any object that opens or closes.
Before mounting the sensor, make sure you test
if the location you install the sensor is in range
from your telephone base.
•
Use adhesive tape to hold the sensor
temporarily in place.
•
Mount the sensor to a higher position to
avoid obstacles or blockages. Depending
on surroundings and obstructing factors,
like walls or cabinets, the sensor may not
transmit to the telephone base properly.
1. Take the sensor unit and magnet unit to
the desired mounting location, and use
adhesive tape to hold them temporarily in
place at the object and the frame.
2. Enter the Check signal mode under the
Sensor setup menu at your handset to
test the sensor signal strength.
3. Open the door, window, drawer, cupboard,
or jewelry box again and check whether a
good signal is received at your telephone
base.
NOTES
If No signal or Weak signal message is
•
displayed in Check signal mode, mode, or if
you do not receive an alert when you open the
door, move the telephone base closer to the
mounting location or move the sensor closer to
the telephone base.
•
Depending on surroundings and obstructing
factors, like walls or cabinets, the sensor may
not transmit to the base properly.
After testing the sensor signal strength, mark
the mounting location on the door, window,
drawer, cupboard, or jewelry box and its
respective frame. Then, remove the adhesive
tape and proceed to the mounting process.
NOTES
•
The door images in this installation guide are for
conceptual reference only.
What's in the box
Your product package contains the following items. Save your sales receipt and original
packaging in the event warranty service is necessary.
Sensor unit
Double-sided
Small screw x 2
mounting
(for fixing sensor
tape B
unit's back cover on
the spacer; optional)
Spacer for
Double-sided
Large screw x 2
sensor unit
mounting
(for fixing the
spacer on the
(optional)
tape A
frame; optional)
Overview
Sensor overview
Sensor unit overview
1 – Magnet unit
2 – Sensor unit
1 – Latch button
•
2 – Back cover
3 – P (Pair) button
•
4 – LED light
•
•
5 – Battery compartment case
Mount the magnet unit
Mount the sensor
We recommend you mount the magnet unit
on a door, window, drawer, cupboard, or
jewelry box, and mount the sensor unit on its
Mount with tape
respective frame.
1. Attach mounting tape C onto the
You can use the spacers provided if there is
rectangular area at the rear side of the
a difference in level between the door and
magnet unit,
the frame. The spacer will help to align your
2. Stick the magnet unit onto the door.
sensor to the correct height. You can also
use a spacer if the frame is too narrow or has
some decorative molding.
NOTES
•
You can mount the sensor unit with mounting
tape first, and then use screws later if you
Mount with tape
decide to mount it at that location for long term.
•
Make sure the mounting surface is clean. A
You can choose one out of the four spacers
textured surface or any imperfections to a
with suitable height, and then add it to the
smooth surface can keep the mounting tape
magnet unit.
from making a strong bond.
1. Push the spacer towards the magnet unit
•
Align the magnet unit with sensor unit when
until it securely clicks into place.
mounting.
2. Attach mounting tape C onto the
•
The distance between the sensor unit and
magnet unit must be less than 1 cm (0.4 inch).
rectangular area at the rear side of the
spacer.
3. Stick the magnet unit onto the door.
> 1 cm
(0.4 inch)
< 1 cm
(0.4 inch)
> 1 cm
(0.4 inch)
> 1 cm
(0.4 inch)
Before use
Install batteries to the
Contact Sensor
NOTES
•
Use 2 x AAA batteries. Alkaline batteries are
recommended. If you use other kind of batteries,
the performance of the sensor varies.
•
Do not mix old and new batteries. Do not
Magnet unit
Double-sided
mix alkaline, standard (Carbon-Zinc) or
rechargeable (Ni-Cad, Ni-Mh, etc) batteries.
mounting tape C
•
While you insert the batteries, make sure the
polarities are correct.
•
The batteries operate properly under the
temperature between 0°F (-18°C) and 130°F (55°C).
Spacers for magnet
unit
(optional)
1.
Press the latch button on the sensor to
open the battery compartment case.
2.
Insert two AAA alkaline batteries into the
battery compartment.
Add and register a sensor
You need to register your new VC7002A Contact
Sensor to your VC7151-102A/VC7151-202A/
VC7151-302A telephone system.
To register a Contact Sensor on
VC7151-102A/VC7151-202A/VC7151-302A
telephone system:
1. Press and hold /HANDSET LOCATOR on
Press to open the battery
the telephone base for about 4 seconds until
compartment case.
the IN USE light turns on. The telephone
base shows Registering... Please wait.
2. Press and hold the pair button (P) on
the Contact Sensor, until the LED light
Press and hold to enter the registration
flashes red, to enter the registration mode.
mode.
The telephone base shows Contact X
registered and you hear a beep when the
registration process completes. The registration
Red for a second when the sensor is
process takes about 90 seconds to complete.
powered on.
Flashes red when the sensor is in the
registration mode.
*
Contact X refers to the sensor's name.
X refers to the system-assigned number of the
sensor.
Without spacer
With spacer
*
c c
Need help?
Do you have a question about the VC7002A and is the answer not in the manual?
Questions and answers