Blank Display - Norcold Polar N7V Service Manual

Polar 7 series; polar 8 series gas electric
Hide thumbs Also See for Polar N7V:
Table of Contents

Advertisement

TROUBLESHOOTING FLOWCHARTS - N7LX AND N8LX MODELS, cont'd.

Blank Display

Before starting this procedure:
■ Make sure the vehicle DC voltage to the refrigerator is 10.5 to
16.0 volts.
■ Make sure no other appliance or lighting circuit is connected to
the refrigerator DC circuit.
■ Make sure the DC input of the vehicle is wired into the main
control board according to the Refrigerator Installation Manual.
Touch Power ON button
to turn refrigerator on.
YES
Refrigerator
turns ON?
NO
Measure DC input voltage to main
control board (power board)
at terminals 12VDC and GND.
Check continuity of F1 fuse
located on main control board
(power board).
Measure voltage at main control
board (power board) between
P1-9 (white/violet) and P1-12 (green)
Measure voltage at user interface
(controls) wire harness between P1-1
(green) and P1-5 (white/violet).
NOR000803A
Replace user interface assembly.
www.norcold.com
No problem.
NO
10.5 to
16.0 VDC?
YES
NO
Is fuse intact
(zero ohms)?
YES
NO
10.5 to
16.0 VDC?
YES
NO
10.5 to
16.0 VDC?
YES
Correct DC input
to refrigerator.
Replace fuse
(5-Amp MINI Blade
Automotive style)
Replace main
control board
(power board).
Check connection/continuity of
green wire between main control
board (power board) (P1-12) and
user interface (controls (P1-1).
Check connection/continuity of
white/violet wire between main
control board (power board) (P1-9)
and user interface (controls (P1-5).
Call Customer Service.
49
Blank display.
Possible Cause:
The refrigerator is OFF.
SERVICE MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Polar n7xPolar n8vPolar n8xPolar n8lxPolar n7lx

Table of Contents