TROUBLESHOOTING FLOWCHARTS - N7LX AND N8LX MODELS, cont'd.
Fault Code - "Sr" with audible alarm
Are gas
valve wires
plugged in?
YES
To reset fault, power
refrigerator OFF and
then back ON.
Does
problem
continue?
NOR000706A
Fault Code - "oP" "LI" with audible alarm
On the main control board
assembly (power board),
the limit circuit is open.
NOR000804A
Fault Code - "FL" "- -" with audible alarm
The gas valve is
"mechanically" stuck open.
NOR000709A
www.norcold.com
NO
Correct.
NO
Solved.
YES
Replace main control board assembly
(power board assembly).
Replace the main control board
assembly (power board).
Replace gas train assembly
47
set
CODE
Flashes "Sr" with
an audible alarm.
Possible Cause:
The main control board assembly (pow-
er board) detected an internal fault. This
fault can be displayed in any MODE.
CODE
CODE
Alternately flashes "oP" and "LI"
with an audible alarm.
Possible Cause:
On the main control board assembly
(power board), the limit circuit is open.
CODE
CODE
Alternately flashes "FL" and "--"
with an audible alarm.
A flame is sensed at the burner when
there should be none present.
Possible Cause:
The gas valve is "mechanically" stuck
open. Therefore, the main control board
(power board) senses a flame is pres-
ent at the burner when there should be
none
SERVICE MANUAL