For Polar 7 Series (N7V,N7X or N7LX) models: 7 cu. ft., 2-way, 3-way (only available on X or
LX models),or with ice maker, R.V Refrigerators.
For Polar 8 Series (N8V,N8X or N8LX) models: 8 cu. ft., 2-way, 3-way (only available on X or
LX models),or with ice maker, R.V Refrigerators.
The model numbers of 3-way refrigerators (only available on X or LX models) include ".3".
The model numbers of 2-way refrigerators do not.
Any letters following the above model numbers means a refrigerator option.
Improper installation, adjustment, alteration, service or maintenance can
!
WARNING
cause injury or property damage. Refer to this manual. For assistance
or additional information, contact a qualified installer, service agency, or
the gas supplier.
FIRE OR EXPLOSION HAZARD
!
WARNING
If you smell gas or ammonia:
1. Open Windows
2. Do not attempt to light appliance.
3. Do not touch electrical switches.
4. Extinguish any open flame.
5. Shut off fuel supply.
6. Evacuate immediately and call emergency services.
Failure to follow these instructions could result in fire or explosion, which could cause
property damage, personal injury, or death.
FOR YOUR SAFETY
NORCOLD, Inc.
P.O. Box 4248
Sidney, OH 45365-4248
Do not store or use gasoline or other flammable vapors and liquid in the
vicinity of this or any other appliance.
Installation Manual
English
Norcold Customer Support Dept.
Telephone: 800-543-1219
Fax: 734-769-2332
Web Site: www.norcold.com
Part No. 639300J (8/26/2022)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Polar 7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Norcold Polar 7 Series

  • Page 1 Installation Manual For Polar 7 Series (N7V,N7X or N7LX) models: 7 cu. ft., 2-way, 3-way (only available on X or LX models),or with ice maker, R.V Refrigerators. For Polar 8 Series (N8V,N8X or N8LX) models: 8 cu. ft., 2-way, 3-way (only available on X or LX models),or with ice maker, R.V Refrigerators.
  • Page 2: Table Of Contents

    Table of Contents Safety Awareness .....................................2 Safety Instructions ....................................2 Certification and Code Requirements...............................3 Ventilation Requirements..................................4 Key Refrigerator Dimensions..................................5 Assemble the Enclosure for the Refrigerator............................5 Install the Lower and Upper Vents................................6 Rear wall Installation ....................................10 Install the Decorative Door panels (nonmetal door models)........................10 Install the Refrigerator ....................................
  • Page 3: Certification And Code Requirements

    ANSI Z21.19 / CSA 1.4 standards for installation in mobile homes or recreational vehicles. The refrigerator must be installed in accordance with this “Installation Manual” in order for the Norcold limited warranty to be in effect. In addition, the installation must conform to the following, as applicable:...
  • Page 4: Ventilation Requirements

    If this air flow is blocked or decreased, the refrigerator will not cool correctly. Each NORCOLD model is certified by CSA International for correct ventilation. Install only the certified vents that are listed in this manual.
  • Page 5: Key Refrigerator Dimensions

    Key Refrigerator Dimensions These key refrigerator dimensions are for your reference as necessary (See Art02728). Refrigerator cabinet width w/o trim - 23.47 in. max..1 Refrigerator width overall w/ trim - 24.6 in....2 Refrigerator cabinet to side trim - 0.80 in....3 Refrigerator cabinet height w/o trim......
  • Page 6: Install The Lower And Upper Vents

    Install the Lower and Upper Vents 1. Using the following chart, decide which vents and rough opening (RO) sizes to use: Certified Vent RO Height RO Width Upper Roof Exhaust Cap 622293 Upper Roof Exhaust Vent 616319 24 in. 5 1/4 in. Upper Exhaust &...
  • Page 7 Art 02639 Art 02640 - Make sure the baffles are the full width of the inside of the enclosure. - Make sure that the baffles are no more than 45° from vertical [20]. - Put one baffle between the top rear edge of the refrigerator and the inside edge of the upper exhaust vent opening. - Put the other baffle between the outside edge of the upper exhaust vent opening and the side wall of the vehicle.
  • Page 8 Art 02642 Art 02641 - If the depth of the enclosure is more than 26 inches, install a wood or an aluminum or galvanized sheet solid box baffle [21] in the rear of the enclosure (See Art 02641 and Art 02642). - Make sure that the bottom of the solid box baffle is 18 inches to 18 1/2 inches above the bottom of the enclosure [17] (4 1/4 inches to 4 3/4 inches above the top of the lower intake vent opening REF) [18].
  • Page 9 Only use an upper side-wall exhaust vent on refrigerator models that CAUTION are equipped with a fan. If you use an upper side-wall exhaust vent on a refrigerator model that is not equipped with a fan, the refrigerator cooling performance will be poor. - Make sure the refrigerator model is equipped with a fan.
  • Page 10: Rear Wall Installation

    - Make sure that the baffle is against the wall of the vehicle at the top of the upper exhaust vent and 1/4 inch or less from the top of the opening for the upper exhaust vent [115]. - Make sure the baffle is the full width of the inside of the enclosure. - When using an upper side-wall exhaust vent: - If the depth of the enclosure is 24 inches or more and is less than 26 inches [27], install a bent aluminum or galvanized steel sheet baffle [26] to the rear of the enclosure (See Art 02644).
  • Page 11: Install The Refrigerator

    Install the Refrigerator Put the refrigerator in position (See Art 02646, Art 02625 and Art 02626): Make sure the combustion seal [28] is not broken, is completely WARNING around the refrigerator mounting flanges, and is between the mounting flanges and the wall of the enclosure. If the seal is not complete, exhaust fumes can be present in the living area of the vehicle.
  • Page 12 Reverse the Door Swing (optional) This refrigerator has cabinet hinges that allow you to change the direction the door opens by moving the hinges to the opposite side. It is recommended this be done before installing the refrigerator into the enclosure. 1.
  • Page 13: Connect The Electrical Components

    Art 02636 Art 02635 3. Change the position of the door handles (See Art 02630): - Remove the screws, [41] door handle, [70] latch pin [363] and spring [362] from each door. - Put the lower door handle on the upper door and the upper door handle on the lower door. - Attach each door handle with the screws.
  • Page 14: Connect The 12 Volts Dc Supply

    Connect the 12 volts DC supply: As the distance from the vehicle battery to the refrigerator increases, the correct AWG wire size and fuse size also increases. If the wire size is too small for the distance, a voltage drop occurs. The voltage drop decreases the DC input voltage to the main control board which could then affect cooling performance.
  • Page 15: Connect The Propane Gas Components

    - Make sure that the materials used for the gas supply line obey both the current ANSI A 119.2 (NFPA 1192) and CSA Z240 Standards on Recreational Vehicles. Norcold recommends the use of 3/8 inch copper tubing as the gas supply line and requires a 3/8 inch SAE (UNF 5/8-18) male flare fitting as the connection to the refrigerator.
  • Page 16: Examine The Gas Supply System For Leaks

    Examine the gas supply system for leaks: Do not allow the leak detecting solution to touch the electrical components. Many liquids are electrically WARNING conductive and can cause electrical shorts and in some cases, fire. Use a leak detecting solution to examine the gas supply line and all propane gas connections for leaks. If you use compressed air for the test: - The pressure of the compressed air at the manual shut off valve of the refrigerator must not be more than 1/2 psig (14 inches Water Column).
  • Page 17: Operating The Refrigerator Controls (N7V And N8V Models)

    30 second trial for ignition will commence. It may be necessary to repeat this procedure 2 to 3 times before expelling all the air from the LP gas supply line. If after repeated attempts, a flame is not established, stop and consult your local dealer or Authorized Norcold Service Center. Automatic mode operation: - Touch and release the ON / OFF button [30] to turn the refrigerator on.(See Art 02628)
  • Page 18: Operating The Refrigerator Controls (N7X And N8X Models)

    Automatic mode operation: (N7X and N8X models) Control boards are extremely sensitive. NOTICE Evidence of tampering or removal from MODE NORCOLD protective case will VOID any warranty. - Touch and release the ON/OFF button [30] to turn the refrigerator 30 185 on.(See Art 02627)
  • Page 19: Automatic Mode Operation

    - Touch the TEMP SET button [32] as needed to set the temperature setting. - Number one (1) shown in the display [187] is the warmest MODE setting. NORCOLD AUTO CODE - Number nine (9) shown in the display [187] is the coldest setting.
  • Page 20: Manual Ac Mode Operation

    If neither 120 volts AC nor propane gas are available to the refrigerator : - The fault codes “no AC” and then “no FL” show in the display and an audible alarm sounds. - Refer to the “Fault Codes” section of this manual for any faults displayed. If an energy source is available to the refrigerator but is not operating correctly: - While operating in the Automatic mode, the refrigerators electronic controls will automatically select the energy source using the following priorit scheme:...
  • Page 21 - That the manual shut off valve of the refrigerator gas valve is open - That there is no air in the propane gas supply line - Please see your dealer or authorized Norcold Service Center Flash Code “1” This fault indicates a problem relating This is not owner serviceable.
  • Page 22 - That the manual shut off valve of the refrigerator gas valve is open - That there is no air in the propane gas supply line - See your dealer or authorized Norcold Service Center Flash Code “1” This fault indicates a problem relating to This is not owner serviceable.
  • Page 23: Fault Codes (N7V And N8V Models)

    - That the manual shut off valve of the refrigerator gas valve is open - That there is no air in the propane gas supply line - Please see your dealer or authorized Norcold Service Center Alternately flashes “no” “AC” with Turn the refrigerator power OFF and then back ON to reset.
  • Page 25 à proximité de cet appareil ou de tout autre appareil électroménager. Français Service après-vente Norcold Téléphone : 800-543-1219 NORCOLD, Inc. Télécopieur : 734-769-2332 P.O. Box 4248 Site Web : www.norcold.com Sidney, OH 45365-4248 (États-Unis) Réf. 639300H (3/22/2022)
  • Page 26 Table des matières Signalisation de la sécurité ..................................2 Consignes relatives à la sécurité ................................2 Certification et codes à respecter ................................3 Consignes relatives à la ventilation ................................4 Dimensions importantes du réfrigérateur ..............................5 Assemblage de l’enceinte destinée au réfrigérateur ..........................5 Installation des bouches de ventilation supérieure et inférieure .......................6 Installation de mur arrière ..................................10 Installation des panneaux décoratifs de porte (modèles à...
  • Page 27: Certification Et Codes À Respecter

    Z21.19 / ACNOR 1.4 en ce qui concerne l’installation dans des caravanes résidentielles ou véhicules de loisir. Pour que la garantie limitée Norcold puisse entrer en vigueur, l’installation du réfrigérateur doit être conforme au présent « Manuel d’installation ». De plus, elle doit respecter les éléments suivants, lorsqu’ils sont applicables :...
  • Page 28: Consignes Relatives À La Ventilation

    Le système de ventilation de chaque modèle NORCOLD est homologué par la section International de l’ACNOR. Installer uniquement les bouches de ventilation homologuées qui sont spécifiées dans ce manuel.
  • Page 29: Dimensions Importantes Du Réfrigérateur

    Dimensions importantes du réfrigérateur Ces dimensions importantes du réfrigérateur sont données à titre de référence en cas de besoin (voir Art. 02623). Largeur de la caisse du réfrigérateur sans garniture - 23,47 po max........1 Largeur totale du réfrigérateur avec garniture - 24,6 po..........2 Distance entre la caisse du réfrigérateur et la garniture latérale - 0,80 po........
  • Page 30: Installation Des Bouches De Ventilation Supérieure Et Inférieure

    Installation des bouches de ventilation supérieure et inférieure 1. En se servant du tableau suivant, décider des tailles de bouches de ventilation et de découpes (D) à utiliser : Bouche de ventilation certifiée hauteur SO Largeur SO Came d’échappement supérieure de toit 622293 Bouche d’échappement supérieure de toit 616319...
  • Page 31 Art 02639 Art 02640 - Veiller à ce que les déflecteurs fassent toute la largeur de l’intérieur de l’enceinte. - S’assurer que les déflecteurs ne sont pas à plus de 45° de la verticale [20]. - Mettre un déflecteur entre le bord supérieur arrière du réfrigérateur et le bord intérieur de l’ouverture de la bouche d’échappement supérieure.
  • Page 32 Art 02642 Art 02641 - Si la profondeur de l’enceinte est de plus de 26 po, installer un déflecteur en forme de boîte pleine, en bois, en aluminium ou en tôle galvanisée [21] à l’arrière de l’enceinte (voir Art. 02641 et 02642). - S’assurer que le bas du déflecteur en forme de boîte pleine se trouve entre 18 po et 18 1/2 po au-dessus du bas de l’enceinte [17] (4 1/4 po à...
  • Page 33 Utiliser seulement une bouche d’échappement supérieure de paroi ATTENTION latérale sur les modèles de réfrigérateurs équipés d’un ventilateur. Si l’on utilise une bouche d’échappement supérieure de paroi latérale sur un modèle de réfrigérateur qui n’est pas doté d’un ventilateur, les performances de réfrigération seront médiocres. - S’assurer que le modèle du réfrigérateur est équipé...
  • Page 34: Installation De Mur Arrière

    - S’assurer que le déflecteur se trouve contre la paroi du véhicule en haut de la bouche d’échappement supérieure et à 1/4 po ou moins du haut de l’ouverture de cette bouche [115]. - Veiller à ce que le déflecteur fasse toute la largeur de l’intérieur de l’enceinte. - Lors de l’utilisation d’une bouche d’échappement de paroi latérale supérieure : - Si la profondeur de l’enceinte est de 24 po ou davantage mais moins de 26 po [27], installer un déflecteur cintré...
  • Page 35: Installation Du Réfrigérateur

    Installation du réfrigérateur Placer le réfrigérateur en position (voir Art. 02646, 02625 et 02626) : S’assurer que le joint de combustion [28] n’est pas rompu, AVERTISSEMENT qu’il entoure complètement les brides de montage du réfrigérateur et qu’il sépare ces brides de la paroi de l’enceinte.
  • Page 36 Inversion du pivotement de la porte (en option) Ce réfrigérateur est équipé de charnières de caisse vous permettant de changer le sens d’ouverture de la porte. Il est recommandé de le faire avant d’installer le réfrigérateur dans l’enceinte. 1. Retirer les portes (voir Art. 02637) : - Retirer les bacs de rangement des portes.
  • Page 37: Connexion Des Composants Électriques

    3. Changer la position des poignées de porte (voir Art. 02630) : - Retirer les vis [41], la poignée de porte [70], la goupille de verrouillage [363] et le ressort [362] de chaque porte. - Placer la poignée de porte inférieure sur la porte supérieure et celle de la porte supérieure sur la porte inférieure.
  • Page 38: Branchement À L'alimentation 12 V C.c

    Branchement à l’alimentation 12 V c.c. : Le calibre de fil et la taille du fusible utilisés doivent être d’autant plus grands que le réfrigérateur est éloigné de la batterie du véhicule. Si le fil est de calibre trop petit pour la distance, une chute de tension se produit. La chute de tension réduit la tension c.c. d’entrée sur le tableau de commande principale, ce qui pourrait ensuite affecter les performances de refroidissement.
  • Page 39: Branchement Des Éléments Du Gaz Propane

    - S’assurer que les matériaux utilisés pour le tuyau d’arrivée de gaz respectent à la fois les normes actuelles ANSI A 119.2 (NFPA 1192) et CSA Z240 pour les véhicules récréatifs. Norcold recommande l’utilisation d’un tube en cuivre de 3/8 po comme tuyau d’arrivée de gaz et requiert un raccord mâle conique de 3/8 po SAE (UNF 5/8-18) comme connexion avec le réfrigérateur.
  • Page 40: Recherche De Fuites Dans Le Système D'arrivée De Gaz

    Recherche de fuites dans le système d’arrivée de gaz : Ne pas laisser la solution de détection des fuites entrer en contact avec les composants AVERTISSEMENT électriques. Nombre de liquides sont conducteurs et peuvent poser des risques de court-circuit, voire même d’incendie. Employer une solution de détection des fuites pour vérifier l’étanchéité...
  • Page 41: Utilisation Des Commandes Du Réfrigérateur (Modèles N7V Et N8V)

    2 à 3 fois avant d’expulser tout l’air de l’alimentation GPL. Si après des tentatives répétées, il n’y a pas de flamme, arrêter et consulter le concessionnaire local ou le centre après-vente agréé Norcold. Fonctionnement en mode automatique : - Appuyer sur le bouton ON/OFF (marche/arrêt) [30] et le...
  • Page 42: Utilisation Des Commandes Du Réfrigérateur (Modèles N7X Et N8X)

    Fonctionnement en mode automatique : (modèles N7X et N8X) Les tableaux de commande sont AVIS MODE extrêmement sensibles. La preuve d’une NORCOLD modification ou du retrait de l’étui protecteur entraînera l’ANNULATION de la garantie. 30 185 - Appuyer sur le bouton ON/OFF (marche/arrêt) [30] et le relâcher Art 02627 pour mettre le réfrigérateur en marche (voir Art.
  • Page 43: Mise À L'arrêt - Tous Les Modèles

    - Le chiffre un (1) qui apparaît sur l’écran [187] correspond à la température la plus élevée. MODE NORCOLD AUTO CODE - Le chiffre neuf (9) qui apparaît sur l’écran [187] correspond à la température la plus froide.
  • Page 44: Fonctionnement En Mode Manuel Gpl

    Fonctionnement en mode manuel GPL : - Appuyer sur le bouton ON/OFF [30] et le relâcher pour mettre le réfrigérateur en marche. - Appuyer sur le bouton MODE [31] jusqu’à ce que l’icône AUTO s’éteigne et que seule l’icône FLAME (FLAMME) [289] reste allumée. - Appuyer sur le bouton TEMP SET (réglage température) [32] selon les besoins pour régler la température.
  • Page 45 Ce n’est pas propriétaire d’un entretien. Veuillez consulter votre secondes, répète chauffant. revendeur ou le centre de service autorisé Norcold clignote en rouge, sur deux (2) fois, est de cinq (5) Ce défaut est dans le réfrigérateur des Mettez le réfrigérateur hors tension puis à nouveau pour réinitialiser.
  • Page 46 Ce n’est pas propriétaire d’un entretien. Veuillez consulter votre secondes, répète chauffant. revendeur ou le centre de service autorisé Norcold clignote en rouge, sur deux (2) fois, est de cinq (5) Ce défaut est dans le réfrigérateur des Mettez le réfrigérateur hors tension puis à nouveau pour secondes, répète...
  • Page 47: Codes D'anomalie (Modèles N7V Et N8V)

    - que le robinet d’arrêt manuel du réfrigérateur de la valve à gaz est ouverte - qu’il n’y a pas d’air dans la conduite d’alimentation en gaz propane - Veuillez consulter votre revendeur ou le centre de service autorisé Norcold Clignote en «no» «AC» avec une Mettez le réfrigérateur HORS TENSION, puis sous tension pour réinitialiser.