  • Page 1: Table Of Contents

    3400 Contents Introduction Installation Selecting the rear connector Configuration Setting the re-clock speed LED indicators Trouble shooting COSMOS Status Monitoring Specification Ordering information Technical Manual...
  • Page 2: Introduction

    3400 Introduction The 3400 is a serial digital video distribution amplifier designed to be used in the ICON series of 1RU or 3RU frames. It offers up to ten equalised and re-clocked serial digital outputs and takes both 20mm and 30mm rear connectors. Automatic or manual standard selection of all data rates up to 360Mbit/s is provided.
  • Page 3 Digital Video Reclocking DA Technical Manual...
  • Page 4: Installation

    3400 Installation For module installation instructions please refer to the appropriate ICON rack frame section of the manual Selecting the rear connector The 3400 may be used with either the 20mm K3400.2 rear connector providing five outputs or the 30mm K3400.3 rear connector providing ten outputs. Only the first five, non-inverting outputs can be used for ASI.
  • Page 5: Configuration

    Digital Video Reclocking DA Configuration Setting the re-clock speed The re-clocking speed can be automatically determined by the module or manually selected. If COSMOS control is used, the re-clock speed can also be made remotely. Use SW1 to make the selection. 143MB 177MB 270MB...
  • Page 6: Led Indicators

    3400 LED indicators The module is equipped with the following indicators to provide a means of monitoring operation: Indicators Colour Function Error Internal PLL not locked No I/P No input detected 143Mb Yellow 143M/bit/s re-clock speed 177Mb Yellow 177M/bit/s re-clock speed 270Mb Yellow 270M/bit/s re-clock speed...
  • Page 7: Trouble Shooting

    Digital Video Reclocking DA Trouble shooting The Error and No I/P LEDs are lit • check that a serial digital video signal is connected to the rear connector input The Error (No lock) LED is lit • check that the input signal is a valid serial digital video signal with a basic clock rate of 143, 177, 270 or 360 Mbit/s.
  • Page 8: Cosmos Status Monitoring

    In addition, the module is programmed with the following information, which can be read by the status monitoring controller: • module present • module type • module bar code • module issue no For further details of the Pro-Bel status monitoring system please refer to the COSMOS status monitoring manual. Issue 1...
  • Page 9 Digital Video Reclocking DA Technical Manual...
  • Page 10: Specification

    3400 Specification Inputs Number and type: One serial digital video input to EBU Tech 3267E, SMPTE 259M - ABCD Impedance: 75W unbalanced Outputs Number and type: Ten as input equalised and re-clocked, only 5 available with 20mm rear panel Compatibility: All outputs are compatible with SDI/SDTI.
  • Page 11 Digital Video Reclocking DA LED indicators Data rate 143Mbit/s - yellow Data rate 177Mbit/s - yellow Data rate 270Mbit/s - yellow Data rate 360Mbit/s - yellow Auto re-clock ended - yellow No Input - red Error, PLL not locked - red Remote control mode - yellow Power OK - green Technical Manual...
  • Page 12: Ordering Information

    3400 Ordering information ICO-3400-2000 SDI/ASI Distribution Amplifier with 20mm rear panel providing 5 outputs ICO-3400-3000 SDI/ASI Distribution Amplifier with 30mm rear panel providing 10 outputs (5 ASI) Issue 1...