Electrical installation

Contents of this chapter

This chapter describes the electrical installation of the inverter.

Insulation test

Inverter

The inverter is tested for insulation at the factory. Do not perform voltage tolerance or
insulation resistance tests on any part of the inverter.

AC output cables

Make sure that the insulation of the AC output cable obeys the local regulations before you
connect it to the inverter.

PV generator

Make sure that the insulation of the PV generator obeys the local regulations and the
manufacturer instructions. The PV generator must be completely disconnected from the
inverter during the insulation test.