Installation Instructions P .2
For models: FLSMDPC10BOPIR, FLSMDPC20BPIR,
FLSMDPC30BPIR, FLSMDPC50BPIR
1.1.
Switch on power supply, the sensor will stabilise for 15 seconds.
1.2.
The lamp will light on and off twice automatically then default to sensor mode. When the following two conditions
occur simultaneously the lamp will be lit:
1.2.1.
Ambient light is lower than the setting value (LUX).
1.2.2.
Movement of a live body or warm object within the detection area.
2.
Manual override (pulse override).
2.1.
Turn off the switch then turn on quickly, make sure the interval time is shorter than six seconds.
2.2.
The lamp will switch to normal lighting mode enabling continuous lighting without the use of the sensor function
until user switches off.
Note: The sensor mode and normal lighting mode could be cyclically switched, if the power-off time is over ten seconds,
the sensor will default to the sensor mode again when in a power-on state.
PIR Sensor Control
Delay Settings:
Delay time adjustable between 10 seconds - 5 minutes (5 seconds - 1 minute adjustable)
Maximum physical adjustable angle of 270°.
When the light is on, product will reset delay time and keep the light on when detected new signal.
When the light is off, it requires four seconds to re-stabilise.
Detection Illumination Settings:
Detect environment illuminance range 2-2000lux.
Max adjustable angle of 270°.
Detection Distance Settings:
Detect distance is maximum eight metres adjustable.
Max adjustable angle of 270° (physical).
On the rear of the sensor are dials:
1.
Lux - Provisionally turn the control fully to the moon symbol, in this setting the sensor is inactive during daylight. At
dusk, when the light level is at the desired level, adjust the dial towards the sun symbol until the floodlight turns on.
Note: This fitting does not have a walk test facility. Even with the dial turned fully clockwise, the light may not switch on
during bright conditions.
2.
Time - Turn the dial fully anti-clockwise, the floodlight will stay on for five seconds. Turn the dial fully clockwise, the
floodlight will stay on for six minutes.
3.
Sensitivity - Turn the dial fully anti-clockwise for a one metre detection distance. Turn the dial fully clockwise for a
detection distance of eight metres.
Attention:
Adjust the three function dials with caution to avoid damage.
Guarantee
This product is guaranteed for a period of two years from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C. date label, installation
in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The guarantee is also invalidated if the luminaire has
been Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept
responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice.
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield,
S6 1QS
PRN WEE/BJ1331XR
F
Product is suitable for
mounting on flammable
material
E: sales@redarrowtrading.com
Product complies with
all relevant European
standards
T: 0800 195 0006
F: 0870 043 3946
www.redarrowtrading.com

Advertisement

loading

This manual is also suitable for:

Flsmdpc20bpirFlsmdpc30bpirFlsmdpc50bpir