Mitsubishi Electric MELSEC FX2N-2LC User Manual page 91

Temperature control block
Hide thumbs Also See for MELSEC FX2N-2LC:
Table of Contents

Advertisement

FX2N-2LC Temperature Control Block
M15
Temperat
ure
control
ready flag
M8000
TO
K 0
K 70
P
TO
K 0
K 71
P
TO
K 0
K 72
P
TO
K 0
K 73
P
TO
K 0
K 79
P
TO
K 0
K 81
P
FROM
K 0
K 0
FROM
K 0
K 1
K4M20
FROM
K 0
K 2
K4M40
FROM
K 0
K 3
FROM
K 0
K 5
FROM
K 0
K 7
FROM
K 0
K 82
K 1
K 1
Input type selection:
Type K (-100.0 to +400.0 °C) for both channels
K 1
K 1
Alarm mode setting:
K 12
K 1
Upper limit deviation alarm with re-wait
Alarm mode setting:
K 13
K 1
Lower limit deviation alarm with re-wait
Temperature rise completion range: 3 °C
K 3
K 1
CT monitor method:
K 0
K 1
ON current/OFF current (initial value)
Flag: BFM #0 → M0 to M15
K4M0
K 1
Event (CH1): BFM #1 → M20 to M35
K 1
Event (CH2):
K 1
BFM #2 → M40 to M55
Temperature measured value (PV):
BFM #3 (CH1) → D3
D 3
K 2
BFM #4 (CH2) → D4
Control output value (MV):
BFM #5 (CH1) → D5
D 5
K 2
BFM #6 (CH2) → D6
Heater current measured value:
BFM #7 (CH1) → D7
D 7
K 2
BFM #8 (CH2) → D8
Set value range error address:
D 82
K 1
BFM #82 → D82
Program Example 8
8
8-5