  • Page 1 User Manual (MM4-8C) (MM4-16C)
  • Page 2: Power Source

    User manual operation guide 1、power source MM4-8C/MM4-16C signal management platform using 100-250v ac voltage power s upply. Power on when push the button<▍>, Power off when push the button<○>. 2、capacitive touch screen MM4-8C/MM4-16C signal management platform uses a 5” capacitive touch screen,w...
  • Page 3 Each particular function button as shown in form button function Video switch select Audio switch select EDIE management System Settings All switch to select Close the output channel selection Save selection key scene Call select key scenes Output channel Input channel Audio and video synchronization switching Main interface...
  • Page 4: Signal Switching

    3、Signal switching MM4-8C/MM4-16C signal management platform use hot plug input/output card slots; Slots 13 ~ 16 are fixed to output, slots 1 ~ 12 are configurable for input or outpu Switch a input to all output channel Simply choose the Video input and touch the screen interface:touch <Input channel number>...
  • Page 5 Save the current status of input and output channels are also called save the current scene, MM4-8C/MM4-16C signal management platform supports up to 32 scenes. If the current status of corresponding video input and output is to be preserved. The capacitive touch in Video Swicher to <Save scene>+<Storage unit number>...
  • Page 6 1, 2, 3. For example, <OUT1> + <IN1> + <IN2> + <IN3>. MM4-8C/MM4-16C signal EDID data management platform support store 16 group, may at any time Save the EDID data updates to the input channel.In an INTERNAL EDID state,...
  • Page 7 If you need to one output channel EDID information stored. In the SAVE EDID state, select output to click to save the location of the EDID. 8、Internet network communication Settings On entering the system Settings menu, select NETWORK menu options. Into the next sub menu view or change the IP address, protocol, port, setting as shown in the figure.
  • Page 8 Elect RESET interface, click on ENTER. for example, 12、RS232 and WAL control command When MM4-8C/MM4-16C signal management platform and the external control devices through RS232 connection, and set can be used after the external control Settings to control the...
  • Page 9 operation. RS232 default setting of Baud 115200bps, 8 data bits, 1 stop bit, no parity. Exampl Basic Example Action ASCII Variables Example String Settin Response String Video switch input Switch into = input(1 ~ input 1 multip >Catob,c matrix max) <C1to2,3<C >C1to2,3<CR>...
  • Page 10 Video Query query corres corres pondin pondin <CR1:3,2:4 #CR<CR> NULL #CR<CR> relati <CR> relati betwee betwee Audio video switch = input(1 ~ intern input matrix max) + A/B into b c = output(1 ~ embed multip >Tatob,c matrix max or ALL) + audio <T1Ato2A,2 >T1Ato2A,2B<CR>...
  • Page 11 output 3A,3B Audio Query query corres corres pondin pondin <TR1A:3A,2 #TR<CR> NULL #TR<CR> relati A:4B<CR> relati betwee betwee Save Save a = Scene location <CR1:3,2:4 >Sa<CR> curren >S10<CR> (1~32max) ,...<CR> scene t state to 10 Call Call scenar a = Scene location <CR1:3,2:4 >Ra<CR>...
  • Page 12 a = Scene location Set the (1~32max) scene1 >SNAMEa: >SNAME10:Meetin <SNAME10:M b = scene 0 name scene b<CR> g<CR> eeting<CR> name(15English "Meeti name char) ng" Query Query #SNAMEa< a = Scene location <SNAME10:M #SNAME10<CR> scene CR> (1~32max) scene1 eeting<CR> name 0 name a = Scene location Set the...
  • Page 13 Gatewa >GATEWAY <GATEWAY:1 a b c d = >GATEWAY:192.16 :a.b.c.d 92.168.2.1 Gatewa address(0~255) 255.25 8.2.1<CR> <CR> <CR> 5.255. Set the Socket >PORT:a< <PORT:1001 Socket a = Server port Server >PORT:1001<CR> CR> <CR> Server port port 1001 >DHCP:a< <DHCP:1<CR Networ 1= 0:no 1:yes Networ >DHCP:1<CR>...
  • Page 14 Comman >CMDEN:a a = 0:no make comman <CMDEN:1<C d can >CMDEN:1<CR> <CR> 1:make d can R> make make Query Query Comman #CMDEN<C comman <CMDEN:1<C NULL #CMDEN<CR> d can R> d can R> make make Comman comman >CSOUND: a = 0:no sound <CSOUND:1<...
  • Page 15 card = port(1 ~ port:2 >HDCP:a, <HDCP:2,0< matrix max) >HDCP:2,0<CR> b<CR> CR> hdcp = 0:OFF 1:ON hdcp switch Daught Close = port(1 ~ card >CPOWER: port 2 <CPOWER:2, matrix max) >CPOWER:2,0<CR> power a,b<CR> power 0<CR> = 0:OFF 1:ON manage supply ment Query query...
  • Page 16 192.16 To TCP 8.88.1 Socket >SEND-SS a = IP >SEND-SS:192.16 00: >SEND-SS:4 server :a:b,c<C b = Server port 8.88.100:1001,T 1001 <CR> send R> c = data EST<CR> send data “TEST ” "system": "run": "Run 000:01:15" "temp": "20~35", Query "ip": status "192.168.8 ("video","scene","...
  • Page 17 Set the system >LANG:a< a = 0:English 1: langua <LANG:1<CR system >LANG:1<CR> CR> Chinese ge is > langua Chines Query Query system #LANG<CR system <LANG:1<CR NULL #LANG<CR> langua > langua > Restar Restar >SOF-RES >SOF-RESTART<CR <SOF-RESTA t the NULL t the TART<CR>...
  • Page 18 Socket Server port:1001 13、Web management MM4-8C/MM4-16C signal management platform support Ethernet web management, in the browser enter the IP address of the MM4-8C/MM4-16C signal management platform, user name and password login to enter the web management interface. For example, NOTE:...
  • Page 19 When LAN ports connection if the direct connect. Need to set equipment of IP network segment and MM4-8C/MM4-16C in the same network segment. The default user and password for user and 123456. The factory default Settings segment for 192.168.88.229 WEB management option Enter into WEB management option can choose video management, audio management, EDID management, scene calls, system Settings.
  • Page 20 Elect Scene call, then click on the corresponding storage channel before it can be scene calls out. (6)、Audio switch: A for internal audio, B for external audio. click A, then clicking All switch, for Internal audio switch to both external and internal click B, then clicking All switch, for external audio switch to both external and internal click A, then clicking A or B, for internal audio switch to A or B.
  • Page 21 (4)、EDID update and save EDID update: Elect output channel or system EDID option, click input channel will can EDID switch to input boards. TO ALL will the EDID update to all input board. As shown in figure, EDID save:Enter on Save EDID interface, elect output channel EDID, then Select system save EDID channel.
  • Page 22 UART option In this option through HDBT input board and HDBT output board of Serial port communication;It can realize RS232 passthrough control function;first choose RX, then choose tx contact. (1)TX:output boards option (2)RX:input boards option. As shown in figure,...
  • Page 23 System option Protect system settings: General settings, Network settings, UART settings, User data, About host, System Update. (1)、General:Buzzer, external command, account password to modify Settings. (2)、Network:IP address, gateway, subnet mask, port, DHCP Settings. (3)、UART:Baud rate, data bits, stop bits, parity bits. (4)、USER DATA:Data backup, data recovery.
  • Page 24 MM4-8C/MM4-16C signal management platform for the modular design, the user can choose different main body, according to the site environment and flexible with different input and output interface card of a MM4-8C/MM4-16C signal management platform.MM4-8C/MM4-16C signal management platform support asymmetric...
  • Page 25 number/Signal A HDBaseT audio and video signals and control signals types The connector RJ-45 8P line terminal type Recommend the STP CAT6/CAT6A and above cable type 1080P Maximum transmission ≤ 60m ≤ 90m distance 4KMaximum ≤ 60m(CAT6A) transmission ≤ 30m(CAT6A) distance Support video HDTV 1080p @60Hz;VESA 1920×1200;4K 30Hz...
  • Page 26 HDBT1 output/HDBT2 output as shown in the figure Light is state light describe function Often destroyed — The corresponding channel no signal input Signal light Normally on - the corresponding channel signal input Often destroyed - power corresponding Power light interface card does not work Normally on - board electricity work accordingly 2、HDMI board card...
  • Page 27 Support video HDTV 1080p @60Hz;VESA 1920×1200;4K standard Support color RGB;YCbCr(4:2:2) YCbCr(4:4:4) space Seamless No support switching EDID management DDC channels, EDID manager HDCP Settings HDCP authorization or not management Support video support standard Support color support space Seamless Single channel transceiver power supply DC +28V or standard switching EDID management -20℃...
  • Page 28: System Diagram

    Technical parameters light describe function Often destroyed — The corresponding channel no signal input Signal light Normally on - the corresponding channel signal input Often destroyed - power corresponding Power light interface card does not work Normally on - board electricity work accordingly System diagram...
  • Page 29: Safety Information

    Safety Information To reduce the risk of electric shock, do not expose this product to rain or moisture. Do not modify the wall plug. Doing so will void the warranty and safety features. If the wall plug does not fit into your local power socket, hire and electrician to replace your obsolete socket.