  • Page 1 DIGITAL CLAMP METER UP TO 400 AMPS P/No. DT910...
  • Page 2 WARNING To avoid possible electric shock or personal injury, follow these guidelines: • Do not use the meter if it is damaged. Before you use the meter, inspect the case. Pay particular attention to the insulation surrounding the connectors. • Inspect the test leads for damaged insulation or exposed metal.
  • Page 3: Panel Description

    INTRODUCTION This manual provides all safety information, operation instruction, specifications and maintenance for the meter, which is compact, handheld, and battery operated. This instrument performs AC/DC voltage, AC/DC Current (clamp), Resistance, Audible Continuity, Diode, Frequency measurements and Non-Contact ACV Detecting(NCV). It is an 3 3/4 digit (4000 counts) auto ranging DMM with DC &...
  • Page 4 SPECIFICATIONS AC VOLTAGE (Auto ranging) Range Resolution Accuracy 400mV 0.1mV ±(1.5% of rdg + 5dgts) 10mV ±(1.2% of rdg + 3dgts) 400V 100mV 600V Input Impedance: more than 10MΩ Frequency Range: 40 to 200Hz DC VOLTAGE (Auto ranging) Range Resolution Accuracy 400mV 0.1mV...
  • Page 5: Control Button Description

    DC CURRENT (Auto ranging) Range Resolution Accuracy AUTO RANGE 4A ±(3.0% of rdg + 5dgts) 10mA AUTO RANGE 200A 100mA ±(2.5% of rdg + 7dgts) 400A FREQUENCY (Auto ranging) Range Resolution Accuracy 10 ~ 1M Hz 1 Hz ±(1.0% of rdg + 2dgts) 1M ~ 10M Hz ±(1.5% of rdg + 4dgts) Input Voltage Limit: Max.250V(<1M Hz) Max.
  • Page 6: Resistance Measurement

    RESISTANCE MEASUREMENT Connect the BLACK test lead to the COM jack and the RED to the VΩ jack. (NOTE: The polarity of the RED lead is positive “+”) Set the function switch at Ω position, connect test leads across the resistance under measurement.
  • Page 7: Frequency Test

    FREQUENCY TEST Connect the BLACK test lead to the COM jack and the RED test lead to the V/Ω Hz jack. Put the range selector at “Hz” position, and connect the test leads across the resistance under measurement. Take the reading from LCD. Note: When test the high Frequency >1MHz, the input Voltage must be less than 10V for getting the accurate value.
  • Page 8: Warranty Statement

    WARRANTY STATEMENT Brown & Watson International Pty Ltd (“BWI”) of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue will under normal use and service be free of failures in material and workmanship for a period of one (1) year from the date of the original purchase by the customer as marked on the invoice.