Table 13: Preparing IMPRES 2 or IMPRES Batteries for Long-Term
Storage - Calibration Not Required (Cont.)
Status
• Discharge or Charge
Complete
• Ready to Store
Fault
• Battery Faulted
• No discharge current
• Capacity too low to
complete charge
Standby
• Battery is waiting to rapid
charge.
• Battery may be too hot,
too cold, or low voltage.
Table 14: Preparing New (Never Calibrated) IMPRES 2 or IMPRES
Batteries for Long-Term Storage - Calibration Required
Status
Charger Powers On
Battery Detected
Charger Display
LONGTERM STORAGE
xx% Rated Cap
Warning:
NOT CHARGEABLE
REMOVE& REINSERT
or
CANNOT DISCHARGE
FOR LT STORAGE
or
STORE INCOMPLETE
Low Capacity:yy%
Warning:
HOT BATTERY
WAITING TO CHRGE
or
COLD BATTERY
WAITING TO CHRGE
or
VERY LOW BATTERY
WAITING TO CHRGE
Charger Display
IMPRES 2
CHARGER
IMPRES 2
BATTERY
or
IMPRES
BATTERY
25
LED Indicator
Battery does not require
Calibration:
Steady Green
Battery requires Calibration, but
Calibration is disabled in charger:
Alternating Amber/
Green
Flashing Red
Flashing Amber
LED Indicator
Green for approximately one
second
Battery requires Calibration, but
Calibration is disabled by Long-
Term Storage:
Alternating Amber/
Green for four seconds