Preparing Electrical Wiring; About Preparing Electrical Wiring; Safety Device Requirements; Installation - Daikin EKHWS150D3V3 Installation Manual

Domestic hot water tank with option kit for air to water heat pump system
Table of Contents

Advertisement

6 Installation

a
b
a
Shower
b
DHW pump for recirculation (field supply)
▪ Domestic hot water tank – Discharge pipe. If a discharge pipe
is connected to the pressure relief device it must be installed in a
continuously downward direction and in a frost-free environment.
It must be left open to the atmosphere.
▪ Domestic hot water tank – Pressure relief valve. A pressure
relief valve (field supply) in accordance with relevant local and
national regulations, and with an opening pressure of maximum
10 bar must be connected to the pressure relief valve connection.
5.4

Preparing electrical wiring

5.4.1

About preparing electrical wiring

WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
legislation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction
MUST
legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
5.4.2

Safety device requirements

The booster heater in the domestic hot water tank is equipped with a
thermal protector (setting 85°C).
WARNING
The switch box lid must only be opened by a licensed
electrician. Switch off the power supply before opening the
switch box lid.
NOTICE
Do NOT install heaters without thermal cut-out.
To reset the thermal protector: first check possible reasons for the
thermal cut-out button being released and when solved press the
reset button located on the thermal protector.
The power supply must be protected with the required safety
devices, i.e. a main switch, a slow blow fuse on each phase and an
earth leakage protector in accordance with the applicable legislation.
Selection and sizing of the wiring should be done in accordance with
the applicable legislation based on the information mentioned in the
table below.
Make sure that a separate power supply circuit is provided for this
unit and that all electrical work is carried out by qualified personnel
according to local laws and regulations and this manual. An
insufficient power supply capacity or improper electrical construction
may lead to electric shocks or fire.
Installation manual
8
comply
with
the
applicable
Fuse
Minimum circuit
ampacity
F2B (field
13 A
supply)
6
Installation
6.1

Overview: Installation

This chapter describes what you have to do and know on-site to
install the system.
Typical workflow
Installation typically consists of the following stages:
1

Mounting the domestic hot water tank.

2
Connecting the water piping.
3
Connecting the electrical wiring.
4
Finishing the domestic hot water tank installation.
6.2

Opening the units

6.2.1
To open the switch box cover of the
domestic hot water tank
6.3
Mounting the domestic hot water
tank
6.3.1
Precautions when mounting the indoor
unit
INFORMATION
Also read the precautions and requirements in the
following chapters:
▪ General safety precautions
▪ Preparation
6.3.2

To install the domestic hot water tank

1 Check if all domestic hot water tank accessories are enclosed.
2 Place the domestic hot water tank on a level surface. Make
sure the tank is mounted level.
Domestic hot water tank with option kit for air to water heat pump
Recommended
Power supply
fuses
20 A
1~ 50 Hz
220-240 V
EKHWS150~300D3V3
system
4P510672-1B – 2018.01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhws200d3v3Ekhws180d3v3Ekhws300d3v3Ekhws250d3v3

Table of Contents