Installer Guide Uno-Ts2 Overview - Russound UNO-TS2 Instruction Manual

Touchscreen
Hide thumbs Also See for UNO-TS2:
Table of Contents

Advertisement

UNO-TS2 Overview for Installers
Note: The following minimum firmware revisions are required for use with the UNO-TS2:
CAV6.6 Rev. 3
CAV6.6 Rev. 4
CAM6.6
CAM Internal AM/FM Tuner
CAM Internal XM Module
ST2 Dual Tuner
ST2-XM (ST2 Chassis)
ST2-XM (XM Module)
SMS3 Media Server
The UNO-TS2 is an RNET-system enabled touch-
screen that functions similarly to the UNO-S2
keypad. It fits into a double-gang 32ci low volt-
age PVC junction box, uses a CAT-5 110 punch-
down connection, and supports one external IR
receiver. Active system status icons appear on
the screen (shared, master, party and do not dis-
turb). An "All On" or "All Off" can be performed
by pressing and holding the power button.
The CAV6.6 or CAM6.6 controller can NOT be
configured from the UNO-TS2. Controller configu-
ration must be performed using an UNO-S2 key-
pad or the PC Power Tool program.
For One UNO-TS2 per Controller
Note: 12V Zone triggers cannot be used
with this keypad configuration.
An RNET controller (CAV6.6, CAM6.6) supports
one UNO-TS2 and up to five UNO keypads per
controller, connected to the UNO System Keypad
Ports located on the back of the controller.
For 2 to 6 UNO-TS2s per Controller
(One UNO-TS2 per Zone)
Each UNO-TS2 must be connected to an SA-ZX3
Keypad Splitter. The SA-ZX3 is powered by a
1201A 1A power supply and uses an RJ-45
CAT-5 patch cable to connect to the controller's
UNO Keypad Port. UNO-S1/S2 keypads can
2.01.16 or higher
3.01.10 or higher
1.01.05 or higher
1.01.01 or higher
2.00.05 or higher
3.00.10 or higher
3.00.10 or higher
2.00.05 or higher
2.00.07 or higher
share the SA-ZX3 with an UNO-TS2, but they
must be configured for the same zone.
After sources are configured in the RNET sys-
tem, they must be configured in the UNO-TS2
using a simple onscreen process under Installers
Setup. The configured source names (up to 6)
appear on the UNO-TS2 main screen, and unas-
signed source buttons remain blank. Custom
source names are set up in the optional PC
Power Tools program, and standard names are
set up with an UNO-S1 or UNO-S2 keypad.
The UNO-TS2 features pre-configured source
templates. Due to the unique screens used for
each source, the UNO-TS2 does not support the
key mapping features of the UNO-S1/S2 key-
pads. Custom key configuration (Key
Configuration menu of controller) is not recom-
mended and may result in unexpected behavior
by the UNO-TS2.
The UNO-TS2 screen blanker darkens the screen
when it has not been touched for a certain
amount of time. A touch to the screen brings the
screen back. This screen blank time can be
adjusted from 0 minutes (disables screen
blanker) to over an hour.
The UNO-TS2 may require future updates for
screens and for firmware. These updates are
performed in a similar fashion as UNO-S2
updates, with a programming cable and a PC.
INSTALLER GUIDE
UNO-TS2 Overview
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents