User manual
food and luxury food moisture meter
humimeter FS3
Version 2.8_en
© Schaller GmbH
2016

Advertisement

loading
Need help?

Need help?

Do you have a question about the humimeter FS3 and is the answer not in the manual?

Questions and answers

Summary of Contents for humimeter.com humimeter FS3

  • Page 1 User manual food and luxury food moisture meter humimeter FS3 Version 2.8_en © Schaller GmbH 2016...
  • Page 2 It is important that no material is left in the measuring chamber when you turn on the device. 3. Switch on the humimeter FS3 by pressing the power button ( ) for 3 sec. 4. The next step is a self calibration. The word “reinitialize”...
  • Page 3 7. Fill up the measuring device with the sample material. The filling needs to be done slowly and constantly to ensure reproducible results. 8. The display shows the measuring result. 9. If the measuring value is blinking, the valid measuring range been exceeded (limits see list on page 5).
  • Page 4 Changing batteries Your new device is provided with batteries. If the batteries are empty, please proceed as follows: 1.) Press with your finger onto the arrow of the battery cap und pull it back. 2.) Remove the empty batteries. 3.) Put four new batteries in the device. Check the right position of the battery poles.
  • Page 5 Calibration curves 300g wheat 300g durum 300g rape 230g pumpkin seed 5..28% 5..28% 5..18% 2..20% 310g peas 300g soybeans 277g scarlet runner 300g rice peeled 5..25% 9..18% 8..25% 9..25% 250g rice unpeeled 300g rice brown 285g raw coffee 285g raw coffee peeled unpeeled 4..30%...
  • Page 6 300g buckwheat Empty Empty reference 5..18% Special Special only for internal products can products can be use! be calibrated or calibrated or existing curves existing curves can be entered! can be entered! Additional calibration curves: On request Schaller GmbH can develop customized calibration curves for your specific product.
  • Page 7: Menu Level Overview

    Keypad symbols Menu level overview Measuring window: Rolling Menu Type selection Power ON / OFF menu Switch upper Switch lower Next calibration curve Save Previouse calibration curve Hold Power off (3 sec.) Watch the saved data Store menu Suppliers data can be added Watch the saved data (logs) Menu:...
  • Page 8 Transfer saved data to the PC To send your saved logs to the PC, connect the humimeter device to your PC using the USB cable that was delivered with your device. Carefully loose the protection cap on your humimeter and plug in the USB mini B connector.
  • Page 9 Print saved data To print your saved data, connect the device to the printer using the printer cable that was delivered with your device. Carefully loose the protection cap on the humimeter. At first plug in this side of the connector having the plastic casing close to the end at the humimeter.
  • Page 10 Each device includes a serial number and the guarantee stamp. If those are broken, no claims for guarantee can be made. In case of a faulty device, please contact Schaller GmbH (www.humimeter.com) or our dealer. Activation of the “super user” function 2 times - Options –...
  • Page 11: Technical Data

    Technical data Resolution of the display 0.1% water content 0.5° C temperature Measuring range 0 up to 40% depending on the material Operation temperature 0 up to +40°C (32 up to 104° F) Storage temperature -20° C to +60° C Temperature compensation automatically Power supply...
  • Page 12: Important ! Please Read

    ! IMPORTANT ! please read Most common reasons for miss readings • Product temperature out of application range Material of a temperature below 0° C resp. above +40°C (32 to 104 °F) may cause faulty measurements. The storage of cold material in a warm storage area usually creates condensed water which may lead to major measuring errors.