2. Thepowersupplymust
beproperlypolarized.
Reverse polaritywill resultin
continuoussparkingof the
electrodes, even after flame
ignition. If the power supply is
not properly polarized, it is the
responsibility of the customer
to have the polarity corrected.
3.
If there is any doubt as to
whether the wall receptacle
is properly grounded
or
polarized, have it checked by
a qualified electrician prior to
installing the cooktop.
4.
Do not plug the cooktop
into Ground Fault Circuit
Interrupter (GFCI) receptacles.
The cooktop spark ignition
module can cause a GFCI to
trip.
Installing the Cooktop
Place and center the cooktop within the cutout.
Secure the cooktop to the countertop utilizing
the four (4) hold-down
brackets provided• Do not
over-tighten
the hold down bolts.
Over tightening the hold down bolts may result
in improper operation of the dual gas burners.
[_
IMPORTANT:
Do not use a hardening
compound or caulking to
permanently seal the cooktop into
place, as the unit must be readily
removable for service. If such a
hardening compound is used,
removal of the unit will be at the
customer's expense.
PGM Hold down
bracket mounting
holes
(both sides)
Electrical
_
//
Hold Down
Bracket Locations
Dedicated
Total
Manifold
Electrical
Model No.
Gas Type
Pressure
Circuit
Connected
Load
Required
PGM304
PGM304LP
PGM365
PGM365LP
Natural
Liquid Propane
Natural
Liquid Propane
5" Water Column
10" Water Column
5" Water Column
10" Water Column
Minimum
Gas Supply
Pressure
6" Water Column
11" Water Column
6" Water Column
11" Water Column
120VAC,
60Hz, 15A
Gas and Electrical
Requirements
0•25 Amps
(o.03Kw)
Connecting the Gas
1.
WARNINGS:
The maximum gas supply
pressure to the regulator must
not exceed 1/2 pound per
square inch (3.5 kPa).
2.
Verify that the proper gas
supply has been provided.
3.
Do not apply excessive
pressure when tightening
connections and fittings.
4.
Do not use plumber's
putty or Teflon tape on gas
compression connections.
It can defeat the proper
sealing of these fittings.
Use
plumber's putty or Teflon tape
only on pipe thread fittings.
5.
Turn all cooktop control
valves to the "OFF" position,
then turn on the gas supply.
Check all supply lines and
connections for leaks using a
soap and water solution. Do
not use a flame to check for
leaks. After verifying that there
are no gas leaks, turn offthe
gas supply to the cooktop by
turning the gas shut-off valve
to the off position.
6.
For LP gas installations, the
LP gas tank must have its own
high-pressure
regulator. This
is in addition to the pressure
regulator supplied with the
cooktop.
Attach the gas pressure regulator (included with
the cooktop) to cooktop pipe nipple inlet. For
tight installations,
the regulator may be installed
upstream from the pipe nipple, anywhere
between the shut-off valve and the cooktop.
[_
IMPORTANT:
To prevent damage to the gas
pressure regulator, install the
regulator only after the cooktop
is mounted in its permanent
position. Ensure that the arrow
on the regulator points in the
direction of the gas flow towards
the cooktop.
Installing the Burner Components
[_
WARNING:
Never attempt to operate the
cooktop with any of the burner
heads, burner caps, or grates
removed.
Grate
Single Cap
Dual_
Cap Cover_b-_
Single Burner
Dual Burner Cap_
_
_
_
Head
Dual Burner Head _
_
Single Burner Base
DC_°:B uRri:grSkirt _'_
Cross Ring
PGM Burner Components
Burner Components
Remove the burner covers, brass burner heads,
burner caps, and porcelain grates from their
shipping packages. Place each burner cover
and burner head onto its corresponding
burner
base, being certain that the alignment tabs
slide into the matching notches in the base.
Set each burner cover and cap on top of its
corresponding
burner head. Place each grate
onto the cooktop, being certain that the rubber
feet are positioned in the locating dimples.
Install a gas shut-off valve (not included with
the cooktop) in the main gas supply line in an
accessible location near the cooktop.
Complete
connection of the gas supply to the cooktop by
installing a minimum
1/2 inch flexible gas line
(not included with the cooktop) between the
pressure regulator and the shut-off valve•