Specifications - Panasonic HG-C1030 Instruction Manual

Micro laser distance sensor hg-c series

Advertisement

Procedure
Measurement display
DOWN: Press for 3 seconds
Response time
setting
High precision
UP /
TEACH
DOWN
UP / DOWN
Output operation
setting
Light-ON
UP /
TEACH
DOWN
UP / DOWN
Sensing output
Normal sensing
setting
mode
UP /
TEACH
DOWN
UP /
DOWN
UP /
DOWN
UP / DOWN
Trailing differen-
tial mode
Hysteresis setting
Hysteresis width
TEACH
UP key
DOWN key : Decreases hysteresis width
UP / DOWN
External input
setting
Zero set function
UP /
TEACH
DOWN
UP / DOWN
Timer setting
No timer
UP /
TEACH
DOWN
UP / DOWN
Display setting
Normal
UP /
TEACH
DOWN
UP / DOWN
Hold setting
Hold OFF
UP /
TEACH
DOWN
UP / DOWN
ECO Setting
ECO OFF
UP /
TEACH
DOWN
UP / DOWN
Reset setting
Reset NG
UP /
TEACH
DOWN
UP / DOWN
Response time
setting
13
ERROR INDICATION
● In case of errors, attempt the following measures.
Error indication
Description
<Hold OFF>
Insufficient amount of reflected light.
The sensing object is out of the sensing range.
<Hold ON>
Measured value blinks
Flash memory is damaged or passed its life expectancy.
Load of the sensing output is short-circuited
causing an over-current to flow.
The semiconductor laser is damaged or
passed its life expectancy.
• W hen zero set is set, the measurement is
not performed normally.
• Since the display setting is set to "Offset",
the zero set function can not be used.
During teaching, the measurement is not per-
formed normally.
System error
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Standard
High speed
UP /
DOWN
Dark-ON
1-point teaching
2-point teaching
Window com-
Window com-
parator mode
parator mode
UP /
DOWN
UP /
DOWN
UP /
DOWN
Rising differen-
3-point teaching
tial mode
Window com-
parator mode
: Increases hysteresis width
Light emitting
Teaching function
stop function
Trigger function
UP /
UP /
DOWN
DOWN
OFF-delay
ON-delay
One-shot
UP /
UP /
DOWN
DOWN
Invert
Offset
UP /
DOWN
Hold ON
ECO ON
Reset OK
Remedy
Confirm that the sensing distance is within the
specification range.
Adjust the installation angle of the sensor.
Please contact our office.
Turn OFF the power and check the load.
Please contact our office.
• C onfirm that the sensing distance is within
the specification range.
• Set the display to any setting except "Offset."
Confirm that the sensing distance is within the
specification range.
Please contact our office.
14

SPECIFICATIONS

Measurement
Type
center 30mm type
NPN output
HG-C1030
Model No.
PNP output
HG-C1030-P
Measurement center
30mm
distance
Measurement range
±5mm
10μm
Repeatability
Linearity
Temperature characteristic
Red semiconductor laser Class 2 [JIS / IEC / GB / FDA (Note 2)]
Light source
Max. output: 1mW, Emission peak wavelength: 655nm
Approx.
Beam diameter (Note 3)
ø50μm
Supply voltage
Power consumption
40mA or less (at 24V DC supply voltage), 60mA or less (at 12V DC supply voltage)
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50mA
• Applied voltage: 30V DC or less
Control output
(Between control output to 0V)
• Residual voltage: 1.5V or less
• Leakage current: 0.1 mA or less
Output operation
Short-circuit protection
Analogue output
Response time
<NPN output type>
NPN non-contact input
• Input conditions
External input
Invalid: +8 to +V DC or Open
Valid: 0 to +1.2V DC
• Input impedance: Approx. 10kΩ
Protection
Degree of pollution
Ambient temperature
-10 to +45°C (No dew condensation or icing allowed), Storage: -20 to +60°C
Ambient humidity
Incandescent lamp: Acceptance surface illuminance 3,000ℓx or less
Ambient illuminance
Operating altitude
Cable
Material
Weight
Approx. 35g (without cable), approx. 85g (including cable)
Applicable standard
Notes: 1) Supply voltage: 24V DC, ambient temperature: +20°C, response time: 10ms, and analogue output value of
measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.
3) This is the size in the measurement center distance. These values were defined by using 1/e
of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting
point may be higher than at the point and this may affect the measurement value.
15
CAUTIONS
● This product has been developed / produced for industrial use only.
● Make sure that the power supply is OFF before starting the wiring.
● If the wiring is performed incorrectly, it will cause a failure.
● Do not run the wires together with high-voltage lines or power lines, or put them in
the same raceway. This can cause malfunction due to induction.
● Verify that the supply voltage variation is within the rating.
● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
● If noise generating devices (switching regulators, inverter motors, etc.) are used
around the sensor mounting area, make sure to connect the frame ground (FG)
terminal of the device.
● Do not use this product during the transient state when the power supply is turned
ON.
● The overall length of the cable can be extended to 10m maximum with a cable
size of 0.3mm
2
or more.
● Make sure that stress by forcible bend or pulling is not applied to the sensor cable
joint.
● Although it depends on the type, light from rapid start type or high frequency
lighting type fluorescent lights, sunlight and etc. may affect the sensing, therefore
make sure to prevent direct incident light.
● This product is suitable for indoor use only.
● Keep water, oil, fingerprints and etc. which reflect light, or dust, particles or etc.
which interrupts the light, away from the emitting / receiving surfaces of this product.
If contaminants adhere to the surface, wipe off with a dust-free soft cloth, or lens
cleaning paper.
● Do not use the sensor in locations where there is excessive vapor, dust or etc. or
in an atmosphere where corrosive gases, etc. is generated.
● Take care that the product does not come in contact with oil, grease, organic sol-
vents such as thinner, etc., strong acid or alkaline.
● Make sure to turn OFF the power supply, before cleaning the light emitting / re-
ceiving windows of the sensor head.
● There is a certain deviation in the directionality of this product. Install the product
using a mounting bracket or similar fitting to allow the adjustment of optical axis.
Measurement
Measurement cen-
Measurement cen-
center 50mm type
ter 100mm type
ter 200mm type
HG-C1050
HG-C1100
HG-C1200
HG-C1050-P
HG-C1100-P
HG-C1200-P
50mm
100mm
200mm
±15mm
±35mm
±80mm
30μm
70μm
200μm
±0.1%F.S.
±0.2%F.S.
0.03%F.S./°C
Approx.
Approx.
Approx.
ø70μm
ø120μm
ø300μm
12 to 24V DC ±10%, Ripple P-P 10% or less
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50mA
• Applied voltage: 30V DC or less
(Between control output to +V)
• Residual voltage: 1.5V or less
(At 50mA sink current)
(At 50mA source current)
• Leakage current: 0.1 mA or less
Switchable either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5V (at alarm: +5.2V)
• Output impedance: 100Ω
Switchable between 1.5ms / 5ms / 10ms
<PNP output type>
PNP non-contact input
• Input conditions
Invalid: 0 to +0.6V DC or Open
Valid: +4 to +V DC
• Input impedance: Approx. 10kΩ
IP67 (IEC)
2
35 to 85% RH, Storage: 35 to 85% RH
2,000m or less
2
0.2mm
5-core composite cable, 2m long
Enclosure: Aluminum die-cast, Front cover: Acrylic
EMC Directive Compliance, FDA Standard
Measurement cen-
ter 400mm type
HG-C1400
HG-C1400-P
400mm
±200mm
300μm (measurement
distance 200 to 400mm)
800μm (measurement
distance 400 to 600mm)
±0.2%F.S. (measurement
distance 200 to 400mm)
±0.3%F.S. (measurement
distance 400 to 600mm)
Approx.
ø500μm
2
(approx. 13.5%)