11. Operation

11-1
. Normal Operation Mode(Safe Mode)
When the Main Unit is running in normal operation mode,
Yellow LED is flashing every second.
11-2
. Open the Door
Registered card(or PIN)
11-3
. Exit(Open the Door)
11-4.
Alarm by Unregistered Card(or PIN)
User Access Card(or PIN) is not registered and access is denied,
then Alarm RELAY activates for 2 sec. with "sol-do-sol-do" melody.
Unregistered card(or PIN)
(If you do not want to activate Alarm, then please change settings in section 8-22.
11-5
. Secure Mode
Last exit person can change the mode from Safe Mode to Secure Mode by pressing.
Secure Code from the keypad so that the Alarm will generate by AUX Inputs.
It will canceled automatically when the registered card(or PIN) is present.
11-6
. DURESS Alarm
In case of opening the door by Duress condition, press Duress PassWord
open the door as usual then Duress Alarm(TTL Output) will activate.
User Access Card(or PIN) is granted, Door opens for 3 seconds
To exit, press Exit Button and Door opens for 3 seconds.
-> Change to Secure Mode.
SINGLE DOOR ACCESS CONTROLLER
with "do-mi-sol-do" melody.
- 12 -