Chapter 7: Maintenance
Figure 7-16
Part No. 24001157
Revision C
15. Go to the Transfer "drop-down" menu in the HyperTerminal window
and select Send Text File... (Note that you need to set the Files of
type: field in the Send Text File dialog box to All files (*.*), as
shown in
Figure
Browse to location of the FPGA software upgrade file and select the
appropriate "mcs" file as follows (note that the file name may be
slightly different depending on the revision/version). For example:
The file for selection 0 (zero) is sys_fpga_0406.mcs
This is the system FPGA code.
The file for selection 1 is mux_0204.mcs
This is the Mux FPGA code.
The file for selection 2 is demux_0406.mcs
This is the DeMux FPGA code.
16. When the transfer is complete, select the Store FPGA Checksum
option (enter a
store the FPGA code as shown in
you (Which FPGA Program?) to select the FPGA to store.
NOTE: This step is necessary in order to pass the POST test.
17. Enter a 0 (zero), 1, or 2 corresponding to the FPGA that you are
upgrading. Enter a
Storing the FPGA Program for the DeMux FPGA (option 2)
VersaMux-4000 Operation & Installation Guide
7-13, to access the mcs files.)
7
) from the SOFTWARE UPGRADE UTILITY menu to
Figure
7-16. The system prompts
y
at the prompt to confirm.
Software Upgrade Procedure
Page 7-19