Download Print this page

Specifications - Pelonis HV-1004 Owner's Manual

Utility heater

Advertisement

To operate, connect to properly polarized outlet only. Match wide blade of plug to wide slot and fully insert. Be
sure to plug into a 120V AC, 60Hz outlet. This heater will not operate until the unit is plugged in.
YOUR HEATER IS EQUIPPED WITH A 4-POSITION CONTROL SWITCH.
OFF
OFF
FAN ONLY
FAN
LOW HEAT OUTPUT (900W)
LO
HIGH HEAT OUTPUT (1500W)
HI
Heat Setting Control: Set the power & setting control switch to HIGH for fast warm-up of a room.
Once the room is comfortable, slowly rotate the thermostat control counterclockwise until the heater shuts
off. The thermostat will now maintain the temperature by cycling the heater on and off. Once the room is
comfortable, select a lower power setting to reduce electrical consumption and to prevent the room from
becoming too warm. During particularly cold weather, the LOW power setting may be insufficient to satisfy
the thermostat, select a higher setting for these periods.
Fan Only Setting: To operate fan only setting, turn thermostat to MAX and set the Power & Setting Control
to FAN ONLY setting.
SAFETY FEATURES
Tip Over Switch: As a safety measure, the unit will shut off in the event of it being knocked over. Should this
occur, simply turn the heater off and stand it back up to a regular upright position, then switch it back on.
Overheat Protection: This heater is equipped with thermal cut-off, which temporarily shuts off the heater when
it reaches high temperatures. Once this happens, turn the heater off and unplug. Allow it to cool for 5-10.
minutes. Inspect unit and check to make sure it is not covered with objects. After heater has cooled down,turn it
back on to resume normal operation.
M
o
Power Supply
Power Consumption
Electric Current (A)
1. Before any cleaning, make sure that:
a. The heater is turned OFF.
b. Disconnect power supply at source by removing plug from power outlet.
Your heater is now ready to be cleaned.
2. Regular Cleaning:
a. Do not spray cleaning liquid or other chemicals on the unit.
b.The most common cause of overheating is deposits of dust or fluff entering the heater. Interior dust can
often be removed by using a vacuum cleaner with a crevice tool attachment.
c. To clean enclosure, use a clean, soft and lightly damp cloth to gently wipe off the dirt form the surface
of the unit. Be sure not to wet the heating element and the switches. Allow the unit to dry completely
before using it.
CAUTION:
DO NOT ALLOW WATER TO RUN INTO THE INTERIOR OF THE HEATER AS THIS COULD
CREATE A FIRE OR ELECTRIC SHOCK HAZARD, DAMAGING THE UNIT.
OPERATING INSTRUCTIONS
POWER & SETTING CONTROL

SPECIFICATIONS

d
l e
CLEANING AND MAINTANENCE
THERMOSTAT CONTROL
HV-1004
120 V AC, 60 Hz
1500 W
12.5 A
4
MAX
MIN

Advertisement