Arrow Revolution Installation Instructions Manual

Touchpad acces cylindrical lock

Advertisement

Touchpad Access Cylindrical Lock
Installation Instructions
INSTALLER NOTE:
For Technical Assistance contact contact ARROW LOCK

Advertisement

Table of Contents
loading

Summary of Contents for Arrow Revolution

  • Page 1 Touchpad Access Cylindrical Lock Installation Instructions INSTALLER NOTE: For Technical Assistance contact contact ARROW LOCK...
  • Page 2: Installation

    TABLE OF CONTENTS Installation 9-11 12-16...
  • Page 3: Installation Instructions

    In the box, you should find. . . Installation Instructions Parts Illustrations Battery Cover Latchbolt Outside Inside Inside Inside 4 AA Alkaline Strike Escutcheon Touchscreen Support Lever Batteries Assembly Assembly Handle Tools Lock Installation Door Prep...
  • Page 4 Mark Door Drill Door Note: To avoid splintering wood doors, drill holes (A) and (D) from both sides of the door. Strikes Prepare and Install Strike (Wood Frames Only) 81-2012-0620...
  • Page 5: Prepare Lock For Installation

    PREPARE LOCK FOR INSTALLATION Unpack the Lock Before installation: Inside Support Inside Battery Inside Escutcheon Support Assembly Cover Lever Assembly Screws Handle Determine Hand of the Door Left Hand Reverse Left Hand Right Hand Right Hand Reverse...
  • Page 6 Adjust Lock for Door Thickness (If Necessary) How to Replace, Re-Key or Install Cylinder CAUTION: The cylinders furnished with Revolution lock for use in 1-3/8" doors have a tailpiece that is 1/4" shorter than the standard cylinders that are furnished for 1-3/4" doors. Trying to...
  • Page 7: Install Lock

    INSTALL LOCK Inside Assembly Outside Assembly Escutcheon Screw With Star Washer Scre Touchscreen Cable Support Assembly Screws Motor Cable Touchscreen Cable Retractor Easy / Touchscreen Routing Advanced Cable Mode Connector Latch "Z" Fold (2) 8-32 x 3/4" Flat Head Combination Screws EASY MOTOR EXT-PWR / REMOTE /...
  • Page 8 Directions, Continued CAUTION: Welcome to the Arrow Digital World Note: Refer to programming instructions prior to completion of step 13. Test the Operation of the Lockset Symptom Suggested Action Door is binding a.Check that door and frame are properly aligned and door is free swinging.
  • Page 9 PROGRAMMING 9-11 12-16 Inside Outside Touchscreen Batteries Lockout...
  • Page 10 Menu and Icons Enter Master PIN code (6 digits in length). Touch the screen with palm of hand or Advanced Mode only. Factory default: 123456. fingers to begin and end actions. Enter Supervisor PIN code. Can be 4-12 digits Click the indicated number. in length.
  • Page 11 Definitions I-Button Low Battery Operating Modes Passage Mode Master Code Re-lock Time Shut Down Time Silent Mode Status LED Supervisor Code User Code User Lockout Wrong Code Entry Limit...
  • Page 12 Easy Mode Supervisor User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 Feature Supervisor User Settings Factory Defaults Entrance Authorization Supervisor Code 1234567890 Register/Change User Code Passage Mode Disabled Set Passage Mode Silent Mode Disabled Set Silent Mode Re-lock Time...
  • Page 13 Register / Change PIN Codes (including Supervisor Code) through I-Button Unscrew battery Enter the new Supervisor PIN Enter the first User PIN code (4 - Press the button one Press the button cover hex screw code (4 to 12 digits), followed by 12 digits) followed by the key.
  • Page 14 Advanced Mode Master Supervisor Supervisor Supervisor Supervisor User User User User User User User User User User User User User User User Settings Factory Defaults Settings Master Supervisor User Master Code 123456 Entrance Authorization Lockout Mode Disabled Register/Change Master Code Passage Mode Disabled Register/Change/Delete Supervisor Code...
  • Page 15 Change Default Master Code Before Programming Feature Programming Through Master Code Menu mode, enter number, press the key to continue Register Master Code Register Supervisor Code Register 00-19 Delete Enable All Code Lockout Mode Disable Group Lockout Mode Enable 00-19 Disable 00-19 Enable...
  • Page 16 Set Up Supervisor Codes Menu mode, enter number, press the key to continue Feature Programming Through Supervisor Code Register Register User Code Delete Group User Lockout Mode Enable Disable Enable User Code Lockout Mode Disable Enable Passage Mode Disable Enable Silent Mode Disable To Set Up User Codes...
  • Page 17: Miscellaneous Information

    MISCELLANEOUS INFORMATION To Change Operating Modes Easy / Advanced Setting EASY MOTOR EXT-PWR / REMOTE / EASY ADVANCED ADVANCED EXT-PWR / REMOTE / MOTOR To Return Lock to Programming Defaults without changing the operating mode: EASY ADVANCED Emergency Power Suppy and Battery Replacement...
  • Page 18 Symptom Suggested Action Lock does not respond – door is open The touchscreen will become active when pressed with the palm or fingers in at least and accessible. 3 areas simultaneously. Use a larger area of the palm or fingers and verify contact with at least 3 areas. If touchscreen numbers are visible, check to see if they respond when pressed.
  • Page 19 Easy Mode PIN Code Management Door Number: Door Number: Name PIN Number User Name PIN Number Supervisor Supervisor User 1 User 1 User 2 User 2 User 3 User 3 User 4 User 4 User 5 User 5 User 6 User 6 User 7 User 7...
  • Page 20: Arrow Architectural Hardware

    ARROW USA Arrow Architectural Hardware...