I/O Processor / SAS Controller
Host Bus Type
Cache Protection
Physical Dimensions
Maximum Operating Conditions
MTBF (Calculated)
Operating Voltage
Hardware Warranty
MegaRAID Management Suite
Regulatory Certifications
OS Support
66
Technology and components
9440-8i
SAS3408
PCIe 3.1 x8
N/A
6.127" x 2.712" (155.65 mm x 68.90 mm)
Operating:
10°C to 55°C
20 to 80% non-condensing
Airflow: 300 LFM
Storage:
-45°C to 105°C
5 to 90% non-condensing
>3,000,000 hours at 40C
+12V +/-8%; 3.3V +/-9%
3 years; with advanced replacement option
LSI Storage Authority (LSA)
StorCLI (command-line interface), CTRL-R
(BIOS configuration utility), HII (UEFI Human
Interface Infrastructure)
USA (FCC 47 CFR part 15 Subpart B, class
B); Canada (ICES -003, Class B); Taiwan
(CNS 13438); Japan (VCCI V-3);
Australia/New Zealand (AS/NZS CISPR 22);
Korea (RRA no 2013-24 & 25); Europe
(EN55022/EN55024);
Safety: EN/IEC/UL 60950; RoHS; WEEE
Microsoft Windows, VMware vSphere/ESXi,
Red Hat Linux, SuSe Linux, Ubuntu Linux,
Oracle Linux, CentOS Linux, Debian Linux,
Fedora, and FreeBSD. Contact Oracle
support for Oracle Solaris driver or software
support.
9460-16i
SAS3516
PCIe 3.1 x8
CacheVault
CVPM05
6.127" x 2.712" (155.65 mm x 68.90 mm)
Operating:
10°C to 55°C
20 to 80% non-condensing
Airflow: 300 LFM
Storage:
-45°C to 105°C
5 to 90% non-condensing
>3,000,000 hours at 40C
+12V +/-8%; 3.3V +/-9%
3 years; with advanced replacement option
LSI Storage Authority (LSA)
StorCLI (command-line interface), CTRL-R
(BIOS configuration utility), HII (UEFI Human
Interface Infrastructure)
USA (FCC 47 CFR part 15 Subpart B, class
B); Canada (ICES -003, Class B); Taiwan
(CNS 13438); Japan (VCCI V-3);
Australia/New Zealand (AS/NZS CISPR 22);
Korea (RRA no 2013-24 & 25); Europe
(EN55022/EN55024);
Safety: EN/IEC/UL 60950; RoHS; WEEE
Microsoft Windows, VMware vSphere/ESXi,
Red Hat Linux, SuSe Linux, Ubuntu Linux,
Oracle Linux, CentOS Linux, Debian Linux,
Fedora, and FreeBSD. Contact Oracle
support for Oracle Solaris driver or software
support.