Kaden Installer's Manual
Ducted Gas Heaters
8.2.2 Wiring the Programmable Wall Control to a KE4 Heater
The Programmable control backing plate has 8 terminal points for the connection of control
wires. When connecting, use ONLY the two top terminals marked RH and W. Ensure that the
IMPORTANT
R (RH) and W polarity is correct at both ends of the wire cable. DO NOT remove the factory
fitted link between RH and RC.
A Kaden Programmable Wall Control can be wired directly to a Kaden KE4 heater as follows:
Run a twin wire cable (i.e. figure 8 cable - 0.75mm2) from the heater to the Programmable Wall Control.
Remove the backing plate from the Programmable Wall Control by unclipping it at the sides.
Draw the wires from the wall cavity and feed them through the opening in the backing plate.
Connect the cable to the terminal connections on the backing plate before mounting it to the wall refer to
Diagram 19.
Mount the backing plate onto the wall and then reassemble the controller.
Feed your cable through the grommet located at the base of the unit underneath the access panel.
Connect the other end of the cable to the terminals marked R and W in the heater's electronic control module,
refer to Diagram 19.
KE4
8.2.3 Wiring Programmable Wall Control to KU3, KE3 & KE4 for ADD-ON Cooling
The KU3, KE3 and KE4 heater control board does not have provision for "Add-On" cooling operation. For "Add-
On" cooling operation the unit must be configured, by fitting an Add-On Cooling Relay.
To facilitate Add-On Cooling operation, Kaden accessory Part No. 1621344 must be fitted.
8.3 MANUAL WALL CONTROL INSTALLATION
8.3.1 Wiring the Manual Wall Control to a KU3 Heater
The Manual control backing plate has 8 terminal points for the connection of control wires. When
connecting, use ONLY the two top terminals marked RH and W. Ensure that the R (RH) and W
IMPORTANT
polarity is correct at both ends of the wire cable. DO NOT remove the factory fitted link
between RH and RC.
A Kaden Manual Wall Control can be wired directly to a Kaden KU3 heater as follows:
Run a twin wire cable (i.e. figure 8 cable - 0.75mm2) from the heater to the Manual Wall Control.
Remove the backing plate from the Manual Wall Control by unclipping it at the sides.
Draw the wires from the wall cavity and feed them through the opening in the backing plate.
Connect the cable to the terminal connections on the backing plate before mounting it to the wall refer to
Diagram 20.
28
W
Terminal Block
Terminal Block
Grommet for
control cable
access
Diagram 19
Prommable Wall Control
Back Plate
-
+
W903
R
W904
W905
W
RH
-
+
W
RH
B
RC
G
O
Y
ELEC
GAS