4�3 Installation; 4�3�1 Area To Cut Out In Wall; 4�3�2 Installation Of Flashing - Kaden KU5 Installer Manual

Ducted gas heaters
Table of Contents

Advertisement

Kaden Installer's Manual
Ducted Gas Heaters
4.3 INSTALLATION
4.3.1 Area to Cut Out in Wall
When installing the heater at ground level,
create one rectangular hole to suit the total
POP width and height, all the way to ground
level, (refer to Diagram 14)
Refer to the Base Box for required
wall cut out dimensions.
NOTE
4.3.2 Installation of Flashing
Flashing MUST BE fitted to ensure the ductwork is adequately weather protected.
Step 1. Fit side flashing using existing screws on
cabinet sides.
Step 3. Sit top flashing on top of side flashing
edges. Once in place silicone along the
upstanding face of top flashing.
20
Wall cut-out areas
Base Box
Level concrete base
Ground level
Step 2. Slide top flashing under flashing rail on
Silcone
Step 4. Push the heater up against the wall and
Diagram 14
base box
secure side flashing to the wall.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ku4Ku3Ke4Ke3

Table of Contents