7�1 Outlet Register Chart - Kaden KU5 Installer Manual

Ducted gas heaters
Table of Contents

Advertisement

7.1 OUTLET REGISTER CHART
System Model
KU521
KU5
KU530
KU415
KU420
KU4
KU425
KU430
KU315
KU320
KU3
KU325
KU330
KE415 (300mm)**
KE420 (300mm)**
KE4
KE420XA (350mm)**
KE428 (350mm)**
KE428XA (400mm)**
KE315 (300mm)**
KE320 (300mm)**
KE3
KE320XA (350mm)**
KE328 (350mm)**
KE328XA (400mm)**
** Model and base box duct size.
Airflow figures are based on a total static pressure of 125 Pa for 30 & 35 models and 50 Pa for
other models.
NOTE
Kaden Network 516 modules can only be used on KU4 and KU5 model heaters for adaptive zoning.
A
Airflow
Recommended
Rate (L/s)
Maximum Ceiling
785
12
1000
17
620
10
620
10
630
10
895
16
475
10
540
10
650
11
895
13
498
N/A
581
N/A
622
N/A
896
N/A
1012
N/A
498
N/A
581
N/A
622
N/A
896
N/A
1012
N/A
Table 6
B
Min' Floor / Ceiling
Min' Floor / Ceiling
(Adaptive Zoning Only)
5
7
6
6
6
7
5
5
6
8
4
5
5
8
8
4
5
5
8
8
C
1.5
2
2
2
2
2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25