Kaden Installer's Manual
Ducted Gas Heaters
5. FAN SPEED KU3, KE3 & KE4
5.1 FAN SPEED SETTING FOR KU3, KE3 & KE4 MODELS
There are three fixed fan speed options available on KU3, KE3 and KE4 models, these are:
•
High
- "HIGH" (Factory Default)
•
Medium
- "MED"
•
Low
- "LOW"
5.1.1 To Adjust The Fan Speed
Ensure the power supply to the unit is OFF at the fixed switched socket outlet adjacent to the heater
Access the controls and change as required:
Fan speed high
COMMON
LOW
MED
HIGH
(Factory Default Connections)
•
For High fan speed do not adjust
•
For Medium fan speed move terminal from "HIGH" to "MED"
•
For Low fan speed move terminal from "HIGH" to "LOW"
•
Turn the power back on once complete
When setting the fan speed ONLY move the HIGH, MED and LOW connection, DO NOT alter the
common connection.
IMPORTANT
22
Fan speed medium
COMMON
LOW
MED
HIGH
Diagram 16
Fan speed low
COMMON
LOW
MED
HIGH