Intelligenzia Range C1Ith, C2Ith, & C3Ith - Husky C1H-865 User Manual

Table of Contents

Advertisement

Additional model-specific instructions for
Intelligenzia Range C1ITH, C2ITH, & C3ITH
• These instructions should be read in conjunction with the general operating instructions on pp6&7.
Operating Instructions
TO OPERATE THE ELECTRONIC THERMOSTAT
The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings.
When the unit is operating normally, the display will show the current temperature. To display
the set temperature press the
button. Press the button again to return to normal operation.
To set a new temperature, press
. The display will flash and the current set temperature
will be displayed. Press the
button to increase the set temperature, or press the
button to decrease the set temperature. Press the
display will flash with the new value and then revert to display the cabinet temperature.
Please note:
1. When the chiller is connected to the mains for the first time there will be a short delay
before cooling starts. During this time the Refrigeration Light will flash. After the short
delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller
reaches the set temperature, the Refrigeration Light will be off.
2. If you do not press any button, after six seconds the controller will return to its normal display.
INTELLIGENZIA MODE
The Husky Intelligenzia range is designed for superior energy efficiency. If the chiller is not
opened for two hours, the unit enters its energy-saving Intelligenzia mode. The evaporator fan
and compressor will stop, and the internal temperature will increase from 4°C to 9°C. All these
features are part of the Intelligenzia range's normal operation.
DEFROSTING
The unit defrosts automatically at preset intervals. If however the door is opened too often, or
if the unit if in a location with high humidity, or if the contents are changed more frequently, it
may be necessary to defrost the unit manually. To start or stop manual defrosting, press the
button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a
container placed in the compressor compartment and evaporates. After defrosting is complete,
the unit will return to normal operation.
14
button to save the new setting. The
Circuit Diagrams
C 1 ITH-840/865/900
C2ITH-840/865/900
C3ITH-840/865/900
Wiring Diagram
ELECTRONIC THERMOSTAT SF-402
15

Advertisement

Table of Contents
loading

Table of Contents