Additional model-specific instructions for
Standard Range and Solid Door Range C1, C2, & C3
Combi model C2COMBI
• These instructions should be read in conjunction with the general operating instructions on pp6&7.
Operating Instructions
TO OPERATE THE ELECTRONIC THERMOSTATS
'Beer side' controller
The thermostats have been pre-set, and in most cases it is not necessary to adjust the settings.
When the unit is operating normally, the displays will show the current temperature.
To display the set temperature press the
normal operation.
To set a new temperature, press
. The display will flash and the current set temperature
will be displayed. Press the
button to increase the set temperature, or press the
button to decrease the set temperature. Press the
display will flash with the new value and then revert to display the cabinet temperature.
Please note:
1. When the chiller is connected to the mains for the first time there will be a short delay
before cooling starts. During this time the Refrigeration Light will flash. After the short
delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller
reaches the set temperature, the Refrigeration Light will be off.
2. If you do not press any button, after six seconds the controller will return to its normal
display.
DEFROSTING
The unit defrosts automatically at preset intervals. If however the door is opened too often, or
if the unit if in a location with high humidity, or if the contents are changed more frequently, it
may be necessary to defrost the unit manually. To start or stop manual defrosting, press the
button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a
container placed in the compressor compartment and evaporates. After defrosting is complete,
the unit will return to normal operation.
18
'Wine side' controller
button. Press the button again to return to
button to save the new setting. The

Circuit Diagram

C2CMH-840/865/900

Wiring Diagram

'BEER SIDE' ELECTRONIC THERMOSTAT SF-102B
'WINE SIDE' ELECTRONIC THERMOSTAT ED235
19