Door Magnet Installation - Amana PTAC Service Instructions Manual

Package terminal air conditioner/heat pump
Table of Contents

Advertisement

PROPER INSTALLATION
Viewed from the back with the power block
in upper right corner.
+
-
Battery Holder
Power Connection
-
+
Battery
Holder
Note: For battery connection, the jumper must be placed as
shown above
Power Connection
-
+
Battery
Holder
Note: For 24v powered connection, the jumper must be
placed as shown in preceding graphic.

DOOR MAGNET INSTALLATION

NOTE: MAGNET BUCKETS ARE SHIPPED FROM THE FACTORY
WITH THE MAGNETS IN POSITION A. THE POSITION MAY
CHANGE BASED ON THE DOOR AND DOOR FRAME ALIGNMENT
ON PAGE 23.
Mount the door magnet holder on the front of the door where
it will be as close as possible to the bottom of the motion
sensor but no more then 1/8" from the bottom center of the
motion sensor (DD01E or DD01F) when the door is closed.
Power Connection
-
Wired
Magnet
Connection
+
Pins
Binding Button
Wired
Magnet
Connection
Jumper
on Pins
Battery
Connection
Binding Button
Wired
Magnet
Connection
Jumper
on Pins
Powered
Connection
Binding Button
Select the correct slot in the magnet holder (there are three
slots) to obtain 15/16" from back of sensor mounting plate
to the center of the magnet. (If you can easily slide a
business card between the magnet and the DD01E or DD01F
sensor, unit is properly placed vertically.) See following
image for magnet and sensor alignment.
Screw in place with the 2 screws provided. Open and close
the door to make sure that the magnet holder and motion
sensor will not interfere with normal opening and closing of
the door. See following images.
ALIGNMENT
GUIDES
ON BOTTOM
OF DD01E
CENTER OF MAGNET
SENSOR
MUST BE 15/16" FROM THE
MOUNTING
PLATE
SENSOR MOUNTING PLATE
Do NOT install batteries until you are ready to test the
magnet location with DD01E.
1/8" max.
MAGNET
THE SPACE FROM THE TOP OF
THE MAGNET HOLDER AND THE BOTTOM
OF THE
DD
01E OR DD01F
CANNOT BE MORE THAN 1/8".
The ideal spacing allows a business
card to be easily placed
between the D 01E
D
OR DD01F
sensor
and the magnet holder.
(IN HOLDER)
Security Screw
location (located
on each side of sensor)
MAGNET MUST BE 15/16"
FROM THE SENSOR
MOUNTING PLATE
MAGNET HOLDER MAY EXTEND
ABOVE THE DOOR
(OR THE DD01E OR
DD01F
MAY EXTEND BELOW
THE DOOR FRAME)
TO ENSURE THE MAGNET IS NO MORE
THAN 1/8" FROM THE
BOTTOM CENTER OF THE SENSOR
DOOR
25