mundoclima MUCM-15-W7 Installation Manual And Information Requirements
mundoclima MUCM-15-W7 Installation Manual And Information Requirements

mundoclima MUCM-15-W7 Installation Manual And Information Requirements

Mucm-w7 series medium pressure duct fcu dc

Advertisement

Quick Links

Medium Pressure Duct FCU DC
Installation manual and Information requirements
MUCM-W7
CL04620 to CL04624
English
www.mundoclima.com
www.mundoclima.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUCM-15-W7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mundoclima MUCM-15-W7

  • Page 1 Medium Pressure Duct FCU DC Installation manual and Information requirements MUCM-W7 CL04620 to CL04624 English www.mundoclima.com www.mundoclima.com...
  • Page 2 CONTENT INSTALLATION MANUAL ....................3 INFORMATION REQUIREMENTS ................18 /DWKZd Ed Thank you for selectiong super quality Air Conditiones. To ensure satisfactory operation for many ears to come, this manual should be read carefully before the installation and before using the air conditioner. After reading, store it a safe place.
  • Page 3: Table Of Contents

    Installation manual Medium Pressure Duct FCU DC INSTALLATION MANUAL ,QVWDOO DFFRUGLQJ WR WKLV LQVWDOODWLRQ LQVWUXFWLRQV VWULFWO\ ,I LQVWDOODWLRQ LV GHIHFWLYH LW ZLOO FDXVH ZDWHU OHDNDJH &217(176 3$*( HOHFWULFDO VKRFN DQG ILUH PRECAUTIONS................3 :KHQ LQVWDOOLQJ WKH XQLW LQ D VPDOO URRP WDNH PHDVXUHV INSTALLATION INFORMATION..........4 DJDLQVW WR NHHS UHIULJHUDQW FRQFHQWUDWLRQ IURP H[FHHGLQJ FUNCTIONS &...
  • Page 4: Installation Information

    Installation manual Medium Pressure Duct FCU DC 2. INSTALLATION INFORMATION &$87,21 7R LQVWDOO SURSHUO\ SOHDVH UHDG WKLV PDQXDO DW ILUVW *URXQG WKH DLU FRQGLWLRQHU 7KH DLU FRQGLWLRQHU PXVW EH LQVWDOOHG E\ TXDOLILHG SHUVRQV 'R QRW FRQQHFW WKH JURXQG ZLUH WR JDV RU ZDWHU SLSHV OLJKWQLQJ URG RU D WHOHSKRQH JURXQG ZLUH ,QFRPSOHWH :KHQ LQVWDOOLQJ WKH LQGRRU XQLW RU LWV WXELQJ SOHDVH IROORZ WKLV JURXQGLQJ PD\ UHVXOW LQ HOHFWULF VKRFNV...
  • Page 5: Parts Names

    Installation manual Medium Pressure Duct FCU DC 6. PARTS NAMES 3UHFDXWLRQV EHIRUH LQVWDOODWLRQ 'HFLGH WKH FRUUHFW ZD\ RI FRQYH\LQJ WKH HTXLSPHQW 7KH EHORZ ILJXUHV LV DQ LQVWDQFH PRGHOV ZKLFK ZRXOG EH GLIIHUHQW IURP WKH RQH WKDW \RX SXUFKDVH 7U\ WR WUDQVSRUW WKLV HTXLSPHQW ZLWK WKH RULJLQDO SDFNDJH ,I WKH DLU FRQGLWLRQHU QHHGV WR EH LQVWDOOHG RQ D PHWDO SDUW RI DLU UHWXUQ ER[ WKH EXLOGLQJ HOHFWULF LQVXODWLRQ PXVW EH SHUIRUPHG DQG WKH...
  • Page 6 Installation manual Medium Pressure Duct FCU DC &RQFUHWH LURQ (PEHGGHG EROW *DVNHW 3HQGDQW 3HQGDQW EROW DVVHPEO\ 6XVSHQGLQJ WKH LQGRRU XQLW 8VH WRROV VXFK DV SXOOH\V WR KRLVW WKH LQGRRU XQLW WR WKH SHQGDQW EROW 1HZ FRQFUHWH URXJKFDVW 8VH WRROV VXFK DV JUDGLHQWHU WR VHWWOH WKH LQGRRU XQLW 6HW LW ZLWK HPEHGGHG EXVKHV RU HPEHGGHG EROWV KRUL]RQWDOO\ /DFN RI KRUL]RQWDOLW\ PD\ FDXVH ZDWHU OHDN &RQQHFW WKH GXFW...
  • Page 7 Installation manual Medium Pressure Duct FCU DC 'LPHQVLRQV Unit: mm 7KH TXDQWLWLHV RI WKH IDQV DQG PRWRUV DUH RQO\ IRU UHIHUHQFH SOHDVH SUHYDLO LQ NLQG % $LU UHWXUQ VLGH (OHFWULF FRQWURO ER[ ,QWOHW 2XWOHW &RQGHQVDWH FRQQHFWLRQ SRUW ; +RVWLQJ KROH $LU H[KDXVW YDOYH ' $LU VXSSO\ VLGH Note: To change the water connection side from left to right, please see page 17.
  • Page 8: Pipe Connection

    Installation manual Medium Pressure Duct FCU DC 8. PIPES CONNECTION %HQG :LWK DLU UHOHDVH YDOYH WKH RWKHU VLGH LV ZDWHU LQOHW SLSH 6 VKDSH :KHQ FRQQHFW ZDWHU FROOHFWHU VHW WKH WLJKWHQLQJ WRUTXH WR 1 FP NJI FP DQG XVH D VSDQQHU WR WLJKWHQ LW DV VKRZQ LQ )LJXUH 7KH GLDPHWHU RI FRQQHFWLYH MXQFWLRQ LQ ZDWHU LQOHW SLSH DQG ZDWHU RXWOHW SLSH LV 5&...
  • Page 9: Wiring

    Installation manual Medium Pressure Duct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
  • Page 10 Installation manual Medium Pressure Duct FCU DC :LULQJ 'LDJUDP 230V - 50Hz SPEED SELECTION 230V - 50Hz NOTE: The unit must be powered by L - N with 230V - 50Hz (POWER IN). On the other hand, for the unit to start with one of the 3 speeds, the desired speed must be selected by a 230V - 50Hz signal (SPEED SELECTION).
  • Page 11: Fault And Protection

    &OLHQWV FDQ GLDO WR WKH UHVSRQGLQJ SRVLWLRQ WR FKRRVH WKH PRGHO DQG VWDWLF SUHVVXUH DFFRUGLQJ WR WKH QDPHSODWH DQG DFWXDO VWDWLF SUHVVXUH UHTXLUHPHQWV RI WKH PRGHOV DQG VWDWLF GLDO FRGH WDEOH 0RGHOV DQG VWDWLF GLDO FRGH WDEOH 6WDWLF SUHV VXUH 02'( (by default) MUCM-15-W7 MUCM-19-W7 MUCM-27-W7 MUCM-30-W7 MUCM-36-W7 NOT SET MODELS SW1 SW2 Note: You can see the fan performance curves on page 12.
  • Page 12: Fan Performance Curves

    Installation manual Medium Pressure Duct FCU DC 12. FAN PERFORMVANCES CURVES MUCM-15-W7 12Pa setting: Air Flow (m3/h) 30Pa setting: Air Flow (m3/h) 50Pa setting (by default): Air Flow (m3/h)
  • Page 13 Installation manual Medium Pressure Duct FCU DC MUCM-19-W7 12Pa setting: Air Flow (m3/h) 30Pa setting: Air Flow (m3/h) 50Pa setting (by default): Air Flow (m3/h)
  • Page 14 Installation manual Medium Pressure Duct FCU DC MUCM-27-W7 12Pa setting: Air Flow (m3/h) 30Pa setting: Air Flow (m3/h) 50Pa setting (by default): Air Flow (m3/h)
  • Page 15 Installation manual Medium Pressure Duct FCU DC MUCM-30-W7 12Pa setting: Air Flow (m3/h) 30Pa setting: Air Flow (m3/h) 50Pa setting (by default): Air Flow (m3/h)
  • Page 16 Installation manual Medium Pressure Duct FCU DC MUCM-36-W7 12Pa setting: Air Flow (m3/h) 30Pa setting: Air Flow (m3/h) 50Pa setting (by default): Air Flow (m3/h)
  • Page 17: Connection Side Change Guide

    Installation manual Medium Pressure Duct FCU DC 13. CONNECTION SIDE CHANGE GUIDE To change the connection side from left to right or reverse, please, follow next steps: 1) Unit by default: 2) Uninstall the return air box: 3) Uninstall the drain water pan: 4) Uninstall the heat exchanger: 5) Change the direction of the heat exchanger: 6) Install each part of the unit just like before:...
  • Page 18 Information requirements Medium Pressure Duct FCU DC INFORMATION REQUIREMENTS KDD/^^/KE Z 'h> d/KE h ^ >s KZ ^ K WZKs E Z >KE ^W /E Dh D > Dh D > Dh D > Dh D > Dh D >...
  • Page 20 &: ASK FOR MORE INFORMATION Phone: (+34) 93 446 27 81 eMail: info@mundoclima.com TECHNICAL ASSISTANCE Phone: (+34) 93 652 53 57 www.mundoclima.com...

This manual is also suitable for:

Mucm-19-w7Mucm-27-w7Mucm-30-w7Mucm-36-w7

Table of Contents