Xerox 530 Language And Operations Reference Manual page 71

Table of Contents

Advertisement

r-,-pr
lnt Pas it ion
L
0
I
1
I
2
1
3 "
..
4 T
5
I
6 '
123456789/0123'+56 78910123,.56
789fH2:i456'7~'"i23456
7891112 3456
78~0123456
789 •
[FFF NNNNN·"
CLLL
XXXX A SSSSS3SSSS •••••
-Assembly
Listing Lint'.
F
error Flags
N
Line Number in Dec-1mal (the asterisk occurs only on update!.! lines)
L
Current Value
of
the Execution Location Counter
in
Hexadecimal
X
=
Memory Word in Hexadecimal
A
Address Classification Flag
S
=
Source Image
Figure 9.
Assembly Listing Fonnot
2.
External Referenc.e Summary.
If
the S5 option was
specified on the IXSYMBOL control command, this
summary shows all symbols declared to be primary
or secondary external references.
Only symbol names
are listed, printed with eight entries per line.
3.
Warning Line Summary.
If the DW option was speci-
fied on the XSYMBOL control command, thi'5 summary
lists the total number of statements that contained only
warning (W) flags.
Note that
if
a particular I ine con-
tained both
q
warning and an error flog, it is included
in the error I ine summary, and not the warning I inf>
summary.
EOl
~
3
.~
j
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
EXTENDED
SYHBOL SA}-ll
J
LE
PR0C;R.:\H
'k
0000
/>.
STURE$2
.J~
0001
A
P
0002
A
L
, i(
OOCA
OOCA
M :\,jRITE
OOCE
OOCD
M
:T}~RM
..
}(
TITLE
UEF
h.EF
CNA...1I1E
PROC
STA
seLD
STA
PEND
EQU
EQl1
ASECT
ORG
RES
RES
RES
CSECT
4.
Error Line Summary.
This summary is unconditionol,
and wi" be printed on bath the LO and DO devices.
It lists the total number of error lines in the assembly
(excluding lines containing only warnings).
5.
Error Severity Level.
This summary is unconditional
and wi" be printed on both the LO and DO devices.
It
shows the highest error severity encountered in the
program (0-2).
An assembly I isting of a sample problem is shown in
Figure 10.
00:04
06/07/71
PAGE
1
'EXTENDED SYMBOL SAMPLE PROGRAM'
SAMPLE
DECLARE EXTERNAL DEFINITION
M
:DKEYS ,M: INHEX
DEF
WE
AS EXTERNAL REFERENCES
AF(l)+l
16
AF(
1)
1
2
X'CA'
2
DEFINE
COMK~ND
'STORE$2'
BEGIN PROCEDURE DEFINITION
STORE A-REGISTER
EXCHANGE A
&
E REGISTERS
STORE E-REGISTER
END PROCEDURE DEFINITION
Ol'EFATIUl\; REGISTER EQUATES
DECLARE ABSOLUTE SECTION
BEGINNING AT LOCATION 202.
DECLARE SYMBOLIC TRANSFER VECTOR
ENTRIES TO MONITOR
SERVICE ROUTINES.
DECLARE CONTROL SECTION
Figure 10.
Assembly Listing
,54
Summary Tables

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma 3Sigma 2

Table of Contents