Xerox 530 Language And Operations Reference Manual page 66

Table of Contents

Advertisement

Message
ABORT ASSEMBLY AT LINE y
ASSEMBLER OR MACHINE ERROR
ABORT ASSEMBLY AT LINE Y
DO'S NESTED TOO DEEPLY
Table 2.
Error Messages
(
,
Comments
The assembl er has encountered a sup-
posedly impossible situation during the
assembl y phase. The assembl y is aborted
immediately.
The assembly should be
rerun, specifying a postmortem dump,
and all pertinent documentation for-
warded to the appropriate Xerox
representati ve.
D Os have been nested to a depth
greater than 30.
The assembly is
aborted immediately.
- - - - - - - - - - - - - - - -
-----------------------t------------------------------~
ABORT ASSEMBLY AT LINE Y
DYNAMIC TABLE OVERFLOW
An assembly phase dynamic table has
overflowed.
The assembly is aborted
immediately.
- - - - - - - - - - - - - - - - -
-----------------------t-------------------------~
ABORT ASSEMBLY AT LINE
y
The standard procedure file that has
INCOMPATIBLE S2 FILE·-MUST RECREATE
been specified was created by a dif-
~----------------
- - - - - - - - - - - - - - - - - - - - - - - - -
ABORT ASSEMBLY AT LINE y
I/O ERROR ON xx: BLOCKING BUFFER UNAVAILABLE
t
ferent version of the assembler
It must
be recreated for the current version.
The assembly is aborted immediately.
No blocking buffer has been allocated
for device xx.
This generally indicates
that an insufficient number of blocking
buffers was allocated for XSYMBOL
when it was loaded.
The assembly is
aborted immediately .
. . . - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1------------.-----------------------
ABORT ASSEMBLY AT LINE y
Output or scratch devi ce xx is write-
I/O ERROR ON xx: DEVICE IS WRITE PROTECTED
t
protected.
The assembly is aborted
----A-B-O-R-T-A-S-S-E-M--i-L Y-A-r
-LI-N-E-,~-------------------------T~:m::~:::I::~~nd-Of-I;
lei
nd
i~a~,-'
---
I/O ERROR ON xx: END-OF-FILE ENCOUNTERED
t
has been encountered on device xx.
This generally indicates an assembler,
operating system, or machine error, as
end--of-file indicators on user files are
allowed.
This message cannot occur
for devices 5J and UI.
The assembly is
aborted immediately.
~-----------------------------------------------------------1------ ------------.---------------------~
ABORT ASSEMBLY AT LINE
y
I/O ERROR ON xx: END-OF- TAPE ENCOUNTERED
t
An end-of-tape indi cator has been en-
countered on device xx.
This message
is gi ven for i nsuffi ci ent space on a
RAD file.
The assembly is aborted
immediately.
tThe use of xx refers ,to one of the following operational labels of an assembler fi Ie:
Fi Ie
lJse
File
Use
-~
..
BO
Object languaf Ie output
S2
Standard procedure
DO
Diagnostic outF )ut
ur
II?dote input
GO
Execution obje, :t language output
Xl
Intermed iate source
LO
li sti ng output
X2
Encoded text
SI
Symboll c input
X3
Program I oca I s
SO
Symbol'ic outpu
t
Assembler Diagnostics
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma 3Sigma 2

Table of Contents