Xerox 530 Language And Operations Reference Manual page 68

Table of Contents

Advertisement

Table 2.
Error Messages (cont.)
~--------------.----,-----------.-----------------------------------.------------------------------------,
Message
ABORT ASSEMBLY AT LINE y
RBM CONTROL CARD READ ON SI (cant.)
Comments
no further assemblies in the batch can
be processed.
The abort wi
II
occur at
the completion of the active assembly.
Both the card in error and this error
message are displayed at the end of the
assembly listing.
__________________ . - - - - - - - - -________ . _ _ _ _ +--______ . _______________
---f
ABORT ASSEMBLY AT LINE y
RBM CONTROL CARD READ ON UI
The assembler has read an RBM control
card on the UI device.
The currently
active assembly can be completed, but
no further assemblies in the batch can
b~ precessed.
The abort wi II occur at
the completion of the active assembly.
The card in error is displayed at the
end of the update
I
isting, and this error
message is displayed at the end of the
assembly listing.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ . _ - - - - - - - - - - - + - - - - - - - - - - - - - - - - . - _ . _ - - - - - - - - - - - - - - - -
ABORT ASSEMBLY AT LINE
Y
SIc:UI IS ILLEGAL
The 51 and UI operational labels
tlUVe
been assigned to the same devi ce when
the UI option is specified.
The as-
sembly is aborted immediately.
> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - f - - - - - - - - -.. - - - - - - - -... - - - - -.. -
ABORT ASSEMBLY AT LINE y
SIc=Xl CONFLICTS WITH UI OPTION
The SI and Xl operational labels have
been assigned to the same device when
the UI option is specified.
The as-
sembly listing (on Xl) would not cor-
respond to the actual updated listing.
The assembly is aborted immediately.
r----.--.-------------. . - - ---------------------- ---------------------.------. .
------------~
ABORT ASSEMBLY AT LINE y
SYMBOL TABLE OVERFLOW
The encoder phase symbol table has ex-
ceeded avai lable memory.
The as-
sembly is aborted immediately.
~---------------------
. _ - - - - - - - - - - - - - - - - - - - - - - -
---------.-
..
-----------------------~
ABORT ASSEMBLY AT LINE y
TOO MANY LOCAL SYMBOLS
More than 254 locol symbols have been
declared for a local region.
The as-
sembly is aborted immediately.
f--
----.-------------------f-----------,----
ABORT ASSEMBLY AT LINE y
When an error is detected in an update
UPDATE CONTROL CARD ERROR
control card, the assembler prints an
appropriate message (see UPDATE
CONFLICT and UPDATE ERROR later
in this table) and continues processing
the remainder of the update deck. This
message is printed after the update deck
has been completely scanned for further
updl1te control card errors.
No as-
sembly takes place.
Also, if there are
further assemblies in tfle batch, they
are no!- processed.
t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - . - - -.... - - - - -.. - ... - --------.---. . ----
--------------------_~
UPDATE CONFLICT
LAST SEQ
=
n, m
An error in an update control card has
been detec ted; name
I
y, the range of
the current update command confl i cts
wi th the range of the
I
ast update com-
mand.
This error message is printed
directly after the update control card
in error.
Assembler Diagnostics
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma 3Sigma 2

Table of Contents