Bosch B942 Installation Manual page 2

Touch screen keypad

Advertisement

5 | Status indicators
You can diagnose and troubleshoot the system using the keypad's
status indicators. Refer to Table 5.1.
Status icon
Function
Green check - Ready to turn on (arm)
Red lock - Turned on (armed)
Yellow caution - System trouble
GAS
Blue GAS - Gas alarm
Blue plug - AC power present
Table 5.1: Keypad status icons
6 | Audible tones
The keypad has a built-in speaker that produces several distinct warning
tones. The keypad backlight illuminates when it emits an audible tone.
Tone
Description
Fire signal
When an area is in fi re alarm, the keypad emits
a pulsed, high-pitched bell tone.
Gas signal
When a gas point activates, the keypad emits a
unique high pitched tone.
User alarm
When a user alarm (such as panic and medical
alarms) occurs, the tone sounds for the
programmed amount of time.
Burglary signal
When an area is in alarm, the keypad emits a
steady, high pitched bell tone.
Entrance warning
The keypad emits an intermittent beep tone
during entry delay periods to remind the user
to disarm the area.
Exit warning
The keypad emits an intermittent beep tone
12 | Next
during exit delay.
Invalid button
When an invalid button, or sequence of
buzz
buttons, is pressed, the keypad emits a fl at
buzz tone.
Keypad encoding
The keypad emits a muted beep tone as each
tone
button is pressed to indicate that the entry
was accepted.
Trouble buzzer
When a trouble event occurs, such as a service
alert, the keypad emits a two-tone warble until
you enter a programmed passcode with the
appropriate authority.
Watch tone
A single clean tweedle tone alerts the user
anytime a watch point is faulted.
Table 6.1: Keypad audible tones
7 | Supervision
The control panel supervises all keypads on the SDI2 bus.
If a keypad fails to respond to the control panel, the control panel
declares a Missing Keypad Trouble. When the control panel can
again communicate with the keypad, it restores the Missing Keypad
Trouble.
During a Missing Keypad Trouble, any connected keypad that
maintained contact with the control panel shows the Missing Keypad
Trouble as its idle text, and shows the missing keypad's address. The
communicating keypads also sound a trouble tone. Users can silence
the trouble tone. If no other troubles exist, the tone silences when
the missing keypad restores.
8 | Proximity reader
The proximity reader allows users to use a token or card in place
of a passcode to turn on or off the security system. The proximity
reader supports EM4102 (125 kHz) credentials. The Bosch
ACA-ATR13-RFID tag and Bosch ACD-ATR11ISO-RFID card are
examples.
9 | Addresses, points, and output numbers
To determine the point numbers or output number for each keypad
address, multiply the address number by 10 for the base number, and
then use numbers 1 through 4 in the ones place for the point
numbers. Use 1 in the ones place for the output number.
Examples
For keypad address 01 the point numbers for the input devices are 11
through 14:
Terminal no
1
2
3
4
Input no
11
12
13
14
For output devices connected to the NO and C terminals the output
number is 11.
For keypad address 03 the point numbers for the input devices are 81
through 34:
Terminal no
1
2
3
4
Input no
31
32
33
34
For output devices connected to the NO and C terminals the output
number is 31.
10 | Confi gure Emergency Key functions
To enable the Emergency Key functions use RPS to set the A,B,C Key
Response parameters (KEYPADS/Global Keypad Settings) as follows:
- To enable the Fire key, set A Key Response to Manual fi re alarm.
- To enable the Medical key, set B Key Response to Manual medical
alarm (with or without alarm bell).
- To enable the Panic key, set C Key Response to Manual panic alarm
(invisible or visible).
11 | Firmware updates
Firmware updates require a MicroSD card (2 GB to 32 GB).
Updating the keypad fi rmware:
1.
Go to the Bosch website (us.boschsecurity.com) and download
the fi rmware from the B942 product page.
2.
Save the fi rmware to your MicroSD card.
3.
Ensure the keypad is powered.
4.
Slide the MicroSD card into the MicroSD card slot until it clicks
into place. Refer to Figure 11.1.
5.
The keypad power indicator LED fl ashes during the update. The
keypad also shows Please wait while programming fl ash.
6.
If the keypad shows the calibration screen, follow the on-screen
instructions to calibrate.
7.
When the update completes, the keypad shows Firmware update
successful. Remove SD card to continue.
8.
Remove the memory card from the device. To do so, press down
on the card and quickly remove pressure. The card clicks out of
place. Use your fi ngernail on the upper groove on the card to
slide it out.
9.
The keypad shows the power up screen with the updated
revision number and then shows the Home screen.
R
Y
G
B
1 COM 2 COM 3 COM 4 COM NO C
PWR A
B COM
Figure 11.1: Inserting a MicroSD card
12 | Certifi cations
12 | Keypad cleaning
Use a soft cloth and non-abrasive cleaning solution to clean your keypad
(for example, microfi ber cloth and eyeglass cleaner). Spray the cleaner
onto the cloth. Do not spray cleaners directly onto the keypad.
13 | Certifi cations
Region Certifi cation
US
UL 365 - Police Station Connected Burglar Alarm Units and
Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System Units
UL 1076 - Proprietary Burglar Alarm Units and Systems
UL 1610 - Central Station Burglar Alarm Units
CSFM - California Offi ce of The State Fire Marshal
FCC Part 15 Class B
ANSI/SIA CP-01-2010 - Control Panel Standard - Features
for False Alarm Reduction
CA
Canada CAN/ULC S303 - Local Burglar Alarm Units and
Systems
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm
Control Units
CAN/ULC S545 - Residential Fire Warning System Control
Units
ULC-ORD C1023 - Household Burglar Alarm System Units
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
ICES-003 - Digital Apparatus
14 | Specifi cations
Dimensions
6.2 in x 4.7 in x 0.6 in
(158 mm x 120 mm x 16 mm)
Voltage (input)
12 VDC nominal
Current with prox
200 mA in standby mode
detection disabled
300 mA in alarm mode
Current with prox
300 mA in standby mode
detection enabled
400 mA in alarm mode
Operating temperature 0°C to +50°C (+32°F to +122°F)
Relative humidity
5% to 93% at +32°C (+90°F) non-
condensing
Terminal wire size
18 AWG to 22 AWG (1.02 mm to 0.65 mm)
SDI2 wiring with prox
Maximum distance - wire size
detector disabled
(unshielded wire only):
200 ft (61 m) - 22 AWG (0.65 mm)
520 ft (159 m) - 18 AWG (1.02 mm)
SDI2 wiring with prox
Maximum distance - wire size (unshielded
detector enabled
wire only):
150 ft (46 m) - 22 AWG (0.65 mm)
390 ft (119 m) - 18 AWG (1.02 mm)
Compatibility
B5512/B5512E fi rmware v2.03 and higher
B4512/B4512E fi rmware v2.03 and higher
B3512/B3512E fi rmware v2.03 and higher
D9412GV4 fi rmware v2.03 and higher
D7412GV4 fi rmware v2.03 and higher
Copyright
This document is the intellectual property of Bosch Security Systems, Inc.
and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely
to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the
Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
Touch Screen Keypad
B942/B942W
en Installation Guide