INSTALLATION INSTRUCTIONS Replacement of nozzle and burner primary air WARNINGS adjustment (Fig. 1) - Remove the panel under the oven door. Installation, adjustments and maintenance of the - Slacken grub screw V,undo injector U and remove appliances must be done by authorized installers, in together with aerator Z.
Page 4
ANALYSIS OF SEVERAL FAILURES Place the basket with food to be cooked, slowly in the Difficult or lacking pilot ignition boiling oil, making sure that the froth formed does not –Insufficient gas inlet pressure. spill over the edge of the tank. If this occurs, stop –Obstructed nozzle or main.
The gas valve following references: Burner ignition –Push down the knob and turn it to position –Maintain the knob pushed down and operate on piezoelectric igniter push-button to light the flame. Hold knob in for about 20 seconds then release it and check that the flame stays a light(if the pilot flame turns off repeat the operation).
Page 7
Maa - Land - Country Kaasu - Pa (mbar) OFQG-41 OFQG-61 AT - ES - IT - BE - FI ugelli bruciatori • 2 X 145 4 X 145 PT - CH - FR - SE - DE G20+G25 20/25 GB - LU - DK - IE - GR SI - BG - EE - LV - LT CZ - SK - PL - NO -TR - HR...
Page 8
OFQG-41, OFQG-61 GRUPPO* Pa (mbar) Nom. Min. G25.1 28-30 3B/P G30/G31 28-30 3B/P G30/G31 3B/P G30/G31 42,5 57,5 * Ryhmä - Grupp - Group OFQG-41, OFQG-61 Maa - Land - Country Luokka - Klass - Kaasu - Gas Pa (mbar) Category LU;...