Sekonic LITEMASTER PRO L-478DR-A-EL Startup Manual
Hide thumbs Also See for LITEMASTER PRO L-478DR-A-EL:

Advertisement

Quick Links

Light Meter
Startup Guide
LITEMASTER PRO
L-478DR-EL
L-478DR-A-EL
L-478DR-U-EL
Thank you for purchasing the LITEMASTER PRO L-478DR-EL Series.
This Startup Guide introduces the basic operating functions of this light meter.
For specific details on this light meter, please see the Operating Manual on
the CD-ROM (included in the package).
4

Screen Operations

This section explains how the touch panel on the meter is operated.
Sliding:
Measuring screen
Slide a finger up or down on the
setting value areas to change setting
values.
Touch Operations:
◆Setting value increases when the up arrow (▲) is touched.
◆ S etting value decreases when the down arrow (▼) is touched.
◆ T ouch icon/buttons on the screen to activate their function.
1

Check Included Items

The following items are included with the meter in the package.
Please be sure that everything is included. If any item is missing,
please contact the reseller that sold the meter or the distributor.
Batteries are not included in the package. Please prepare two AAA before
use.
Startup Guide
Safety Precaution
CD-ROM
(L-478DR-EL Series)
(Operating Manual and
Data Transfer Software)
Light Meter
1
Check Included Items
2

Component Names

3

Turning the Power ON

The following items are included with the meter in the package.
The followings are the names of the buttons and parts on the meter.
After inserting the batteries according to the "+" and "-" symbol in
Startup Guide
Please be sure that everything is included. If any item is missing,
please contact the reseller that sold the meter or the distributor.
the battery compartment, press and hold the Power Button for about
1 second to start up meter.
WARNING
* The startup screen will be displayed, followed by the measuring
screen.
English
Batteries are not included in the package. Please prepare two AAA before
use.
retracting ring
Lumisphere
meter off.
* Press and hold the Power Button for about 1 second to turn the
Startup Guide
Safety Precaution
CD-ROM
Lock lever
Lumisphere
Safety Precaution
There is a danger of electrical shock when using high
(L-478DR-EL Series)
(Operating Manual and
voltage strobes.
Data Transfer Software)
panel
Touch
MODEL
SEKONIC
PHILIPPINES
CORPORATION
L-478D
Avoid contacting the terminals.
LITEMASTER PRO
Before using this product, please read this "Safety Precautions" for
proper operation.
 For Proper Operation
Safety Precaution
The WARNING symbol indicates the
English
pacemakers.
This product emits electromagnetic waves.
Do not bring this product close to persons with
Do not use this product in an explosive atmosphere.
WARNING
voltage strobes.
There is a danger of electrical shock when using high
Avoid contacting the terminals.
Measuring
JR10-000001
MADE IN
This product emits electromagnetic waves.
 General Safety Information
The CAUTION symbol indicates the
CAUTION
possibility of death or serious injury if the
product is not used properly.
WARNING
NOTICE
or restrictions when using the product.
operation.
not used properly.
Please read all notes to avoid errors in
The NOTICE symbol indicates cautions
injury or product damage if the product is
possibility of minor to moderate personal
NOTICE
This may damage the product.
• Be careful of sudden emission of lights from strobes.
risk of allergy.
Use of devices emitting electromagnetic waves is
prohibited in hospitals.
• Do not leave this product on car dashboards in hot weather.
• Check the material of the neck strap to see if there is any
CAUTION
Memory
button*
button*
Startup screen
Measuring screen
Do not bring this product close to persons with
L-478DR-EL
• Keep the Operating Manual on hand for reference at any
• Stop using this product when there are any abnormalities.
• This product is intended only for persons with expert
• Do not attempt to repair this product by yourself.
• Monitor children so that they do not touch this product.
• Use this product in a usage environment described in the
• This product is not waterproof.
• Read the Operating Manual before use.
Operating Manual.
time.
knowledge.
long period of time.
at the end of those life, but bring them in at an
and batteries away with the normal household waste
To protect environment, do not through this device
Disposal of Old Equipment
 Information for Users on Collection and
this product and contact the service center.
• Remove the batteries when this product is not in use for a
• When the desired performance is not achieved, stop using
USB
cover latch
Battery
 For Proper Operation
L-478DR-A-EL
port
Power
pacemakers.
Menu
button
Before using this product, please read this "Safety Precautions" for
L-478DR-U-EL
Strap
Soft case
Anti-glare sheet for
button
Battery cover
proper operation.
Do not use this product in an explosive atmosphere.
LCD Screen
Front view
Rear view
L-478DR-EL Series
Strap eyelet
(Elinchrom)
The WARNING symbol indicates the
Synchro terminal
compartment
Battery
Power Button
WARNING
possibility of death or serious injury if the
Use of devices emitting electromagnetic waves is
*Please wait 3 seconds between repeated power on and power off
product is not used properly.
prohibited in hospitals.
Thank you for purchasing the LITEMASTER PRO L-478DR-EL series.
* When using the Spot Meter attachment (separate accessory), you
Bottom view
Battery cover open
*
sessions.
This Startup Guide introduces the basic operating functions of this light meter.
For specific details on this light meter, please see the Operating Manual on
Measuring button functions. For details to do this, please see the
*For explanation purpose, the LCDs illustrated here show the displays of
SEKONIC logo in blue will be displayed as the meter starts up.
The CAUTION symbol indicates the
CAUTION
the CD-RIM (included in the package).
included CD-ROM.
Custom Settings function section in the Operating Manual on the
L-478DR-EL.
CAUTION
possibility of minor to moderate personal
injury or product damage if the product is
• Check the material of the neck strap to see if there is any
4
5
6
7
not used properly.
risk of allergy.
Screen Operations
Measuring Preparations
(Selecting Measuring Mode)
Measuring Preparations
(Setting Lumisphere)

Measuring Light

• Be careful of sudden emission of lights from strobes.
The NOTICE symbol indicates cautions
This section explains how the touch panel on the meter is operated.
T value (shutter speed) priority mode.
This example explains how to measure light using the ambient light
The Lumisphere can be extended or retracted to obtain the best
light measurements for different types of subjects.
This section explains how to take an incident-light measurement
NOTICE
or restrictions when using the product.
NOTICE
Please read all notes to avoid errors in
Measuring screen
Sliding:
enter the Measuring Mode Selection Screen.
1) Touch the Measuring Mode icon at the top left of the Measuring screen to
Selecting Lumisphere setting
Turn the Lumisphere retracting ring to set the aligning mark with the
1) Incident Light
Position the meter in front of the subject with the extended Lumisphere
operation.
• Do not leave this product on car dashboards in hot weather.
setting value areas to change setting
values.
Measuring screen
Selection screen
Measuring Mode
place.
corresponding symbol (extended  /retracted  ) until it clicks into
measure the light falling on the subject.
facing towards the camera's lens axis. Press the measuring button to
This may damage the product.
 General Safety Information
• Remove the batteries when this product is not in use for a
Extended Lumisphere
Retracted Lumisphere
(Lumidisc)
long period of time.
Extended lumisphere is used to
Retracted Lumisphere is used
• Read the Operating Manual before use.
buildings, and other three
measure illumination of people,
subjects such as manuscripts,
• Keep the Operating Manual on hand for reference at any
• When the desired performance is not achieved, stop using
dimensional subjects.
paintings, difference of one or
more light sources for ratio lighting
time.
this product and contact the service center.
and illumination in Lux or Foot-
• Stop using this product when there are any abnormalities.
Touch Operations:
priority mode and return to the Measuring screen.
2) Touch the ambient T icon to select the ambient light T (shutter speed)
candle.
2)
 Information for Users on Collection and
Setting value increases when the up arrow ( ) is touched.
Setting value decreases when the down arrow ( ) is touched.
3) Set the ISO sensitivity and shutter speed corresponding to the camera
* The above screen example shows all of the Measuring Mode visible.
* Models sold in some countries do not display "Foot-candle" due to legal
restrictions
desired area to be measured within the yellow circle and press the measuring
• Do not attempt to repair this product by yourself.
Touch icon/buttons on the screen to activate their function.
settings for shooting.
• This product is intended only for persons with expert
Disposal of Old Equipment
Extended
Lumisphere
Lumisphere
Aligning mark
Lumisphere
Retracted
knowledge.
To protect environment, do not through this device
Shutter speed
ISO sensitivity
• Monitor children so that they do not touch this product.
and batteries away with the normal household waste
• Use this product in a usage environment described in the
at the end of those life, but bring them in at an
Operating Manual.
• This product is not waterproof.
Extended (
)
Retracted (
)
Strap
Soft case
Anti-glare sheet for
LCD Screen
5
Measuring Preparations
(Selecting Measuring Mode)
This example explains how to measure light using the ambient light
T value (shutter speed) priority mode.
1) Touch the Measuring Mode icon at the top left of the Measuring screen to
enter the Measuring Mode Selection Screen.
Measuring Mode
Measuring screen
Selection screen
2) Touch the ambient T icon to select the ambient light T (shutter speed)
priority mode and return to the Measuring screen.
* The above screen example shows all of the Measuring Mode visible.
3) Set the ISO sensitivity and shutter speed corresponding to the camera
settings for shooting.
Shutter speed
ISO sensitivity
2
Component Names
The followings are the names of the buttons and parts on the meter.
Lumisphere
retracting ring
Lock lever
Lumisphere
L-47 8D
Touch
MODE L
panel
CORP ORAT
SEKO NIC
PHILI PPINE
MADE IN
JR 10 -00
Measuring
button*
Memory
button*
Battery
USB
cover latch
port
Power
button
Menu
button
Battery cover
Front view
Rear view
Strap eyelet
Battery
Synchro terminal
compartment
Bottom view
Battery cover open
* When using the Spot Meter attachment (separate accessory), you
may find operation more comfortable by switching the Memory and
Measuring button functions. For details to do this, please see the
Custom Settings function section in the Operating Manual on the
included CD-ROM.
6
Measuring Preparations
(Setting Lumisphere)
The Lumisphere can be extended or retracted to obtain the best
light measurements for different types of subjects.
Selecting Lumisphere setting
Turn the Lumisphere retracting ring to set the aligning mark with the
corresponding symbol (extended  /retracted  ) until it clicks into
place.
Retracted Lumisphere
Extended Lumisphere
(Lumidisc)
Extended lumisphere is used to
Retracted Lumisphere is used
measure illumination of people,
to measure illumination of flat
buildings, and other three
subjects such as manuscripts,
dimensional subjects.
paintings, difference of one or
more light sources for ratio lighting
and illumination in Lux or Foot-
candle.
* Models sold in some countries do not display "Foot-candle" due to legal
restrictions.
Extended
Retracted
Lumisphere
Lumisphere
Lumisphere
Aligning mark
Extended (
)
Retracted (
3
Turning the Power ON
After inserting the batteries according to the "+" and "-" symbol in
the battery compartment, press and hold the Power Button for about
1 second to start up meter.
* The startup screen will be displayed, followed by the measuring
screen.
* Press and hold the Power Button for about 1 second to turn the
meter off.
ION
S
00 01
Startup screen
L-478DR-EL Series
(Elinchrom)
Power Button
*Please wait 3 seconds between repeated power on and power off
sessions.
* When first starting or after replacing batteries, a white screen with the
SEKONIC logo in blue will be displayed as the meter starts up.
*For explanation purpose, the LCDs illustrated here show the displays of
L-478DR-EL.
7
Measuring Light
This section explains how to take an incident-light measurement
using the extended Lumisphere and a reflected-light measurement
using the optional 5-degree Viewfinder attachment.
1) Incident Light
Position the meter in front of the subject with the extended Lumisphere
facing towards the camera's lens axis. Press the measuring button to
measure the light falling on the subject.
2) Reflected Light (with 5-degree viewfinder attachment sold separately)
Look through the finder eyepiece from the position of camera, place the
desired area to be measured within the yellow circle and press the measuring
button to measure the light reflected from the subject.
)
Measuring screen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LITEMASTER PRO L-478DR-A-EL and is the answer not in the manual?

Questions and answers

Summary of Contents for Sekonic LITEMASTER PRO L-478DR-A-EL

  • Page 1: Turning The Power On

    For specific details on this light meter, please see the Operating Manual on Measuring button functions. For details to do this, please see the SEKONIC logo in blue will be displayed as the meter starts up. *For explanation purpose, the LCDs illustrated here show the displays of...
  • Page 2: Measuring Flash Light

    ) to go back to the 7) Press [+] or [-] button to change the total power of http://www.sekonic.com Measuring screen. flash units while each Group lighting ratio is kept. * To go back to Flash Power Control screen, Touch...

This manual is also suitable for:

Litemaster pro l-478dr-elLitemaster pro l-478dr-u-el

Table of Contents