3. CoMMissioninG

Netsilon configuration is performed exclusively on the web server. In order to be able to access the web server it is
necessary to configure the ETH0 port via the front panel keypad and the LCD screen.
i n order not to disrupt Netsilon synchronisation with the other products present on the network, it is
important to maintain identification of the time server.
There are two solutions for accessing the web server:
>
With a DHCP server: automatic assignment of an IP address.
>
Without a DHCP server: manual assignment of a fixed IP address via the control panel in the Netsilon network
menu.
3.1 Factory configuration
The default configuration parameters have been selected to facilitate initial configuration. A single account is
activated on shipment from the factory.
>
Default web server user account:
> Username: bodetadmin
> Password: admin49
T his account cannot be deleted. However, it is strongly recommended to change the password
(see Chapter 4.2.1 Changing the default account password)
When first running Netsilon, the default parameters are as follows:
Functions
Control panel & LCD
screen
USB port
ETH0 Ethernet port
Default status
Unlocked
Language: English
Rotation of information: time,
network, synchronisation and
system status
Enabled
Services:
HTTP: ON
HTTPS: ON
DNS: ON
Console: ON
SSH: ON
IP address not given
Means of configuration
Control panel (technician menu) + web server
Web Server
Web Server
Web Server
Web server
Control panel + web server