Page 1
Owner’s Manual Model: Powered by 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com 603037_RevAE...
Page 2
• VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.
Safety Information Section 1 Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
Safety Information WA R N I N G • During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
002045 To find out what model you have, look at the label on the side of the controller as depicted below: "A" MODEL: SYS, D4 HOME 120V 1.2A 100-240 VAC, 50-60Hz, 425 Clair Road West, Guelph, ON N1L 1R1 Canada SERIAL #: 000001 t.
Installation Item Description Function Restricts water from flowing over the maximum NSF certified flow rate ensuring an adequate UV dose Flow Restrictor is maintained. Allows for sampling of water immediately following UV treatment; necessary in order to confirm Sample valve proper operation of UV system.
Page 8
Installation Prerequisites: • Determine appropriate indoor location of the controller and chamber. Refer to Figure • Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve. • Make sure to turn off the main water supply. •...
Installation • Place sleeve bolt onto the • Insert lamp into the quartz • Connect the green ground • Align connection pins with quartz sleeve, carefully push wire and red strain relief wire the lamp connector by sleeve and thread into sleeve down and hand tighten onto bolt until hard stop.
Page 10
Installation • Ensure only the controller • Shut off the water supply. • Press the pressure button to • Remove sump housing(s) plug is plugged in for entire release the pressure from the using sump wrench. • Close each faucet. disinfection process.
Operation Section 4 Operation 4.1 Control Panel Figure 5 Control Panel Buttons and Display Feature Description Function Lamp timer Counts down from 365 days to show time for annual lamp replacement. display Lamp timer reset After installing a new lamp, press and hold for five seconds to reset Lamp timer to 365. •...
Maintenance Section 5 Maintenance WA R N I N G • Always disconnect power before performing any work on the disinfection system. • Always shut-off water flow and release water pressure before servicing. • Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present. •...
Page 13
Maintenance 5.2 Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced.
Troubleshooting Section 6 Troubleshooting Symptom Possible Cause Possible Solution GFCI and/or breaker tripped Reset GFCI and/or breaker No power Transient voltage surge suppressor (TVSS) damaged Replace TVSS Controller damaged Replace controller and use a TVSS Clean and dry lamp pins and lamp plug, check unit for leaks Connection between lamp and lamp plug is wet GFCI or breaker repeatedly or condensation...
Vertical or horizontal Flow Restrictor* Rated service life of lamp 1 year UV System Certification * - Optional, sold separately for D4 model. Model Maximum rated flow at dose of 16 mJ/cm @ 95% UVT 23 gpm (87 lpm) (5.22 m...
VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
Page 17
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com...
Need help?
Do you have a question about the D4 and is the answer not in the manual?
Questions and answers
I have a new controller for model D, Light won’t start. But Indicators are flashing red and alarm sounds. Help.