NV500
High-Performance Digital Infrared Motion Detector: Installation Manual V1.0
Wiring Diagram
ALARM OUTPUT
12Vdc
N.C.
+
N.C. COM BLK RED TAMPER
Power-up Sequence
1)
LED and relay will toggle on/off for 4 seconds.
2)
Sensitivity level indication: 1 to 5 short flashes to
indicate trimpot position (see B: Sensitivity Settings).
3)
Jumper setting indication. 1 to 4 short flashes to
indicate jumper setting (see C: Jumper Settings).
4)
Detector is ready for alarm detection. Total power-up
sequence = 10 seconds.
Sensitivity Settings
Configure sensitivity via trimpot. Adjust from 1 (lowest sensitivity) to 5
(highest sensitivity), default = 3. The detector must be installed at 2.1
meter or higher).
Viewing sensitivity settings: After power-up, or right after setting the
trimpot to a new sensitivity level, the LED will flash a consecutive amount
of times to show the setting, then adjust the setting accordingly. Thus if
the sensitivity is set to 3, the LED flashes 3 times.
Turn clockwise = Increase sensitivity
Turn counterclockwise = Decrease sensitivity
Warning: The sensitivity trimpot is fragile. Do not overtorque.
NV500
NV500-EI07 Printed in Canada 07/2012
Jumper Settings
The NV500 features 4 pre-programmed profile settings.
The number associated with the profile (1 to 4) depicts the
number of LED flashes when changing jumper settings.
1. Normal (DEFAULT): This profile allows for faster
detection. Use this profile only in normal environments
that have minimal interference.
2. Moderate Risk: This profile provides better false alarm
rejection. Dual-edge processing requires balanced
detection from both sensor's elements and requires that a
beam must be fully crossed even at close range.
3. Pet Immunity: Use the Pet Immunity profile if you have
pets that weigh up to 16 kg (25 lb).
4. Harsh: Use the Harsh profile when the detector is
installed in high-risk environments (potential interference)
and to provide greatly increased false alarm immunity.
SETTING
APSP
1. NORMAL
NORMAL
2. MODERATE NORMAL
3. PET IMM.
HIGH
4. HARSH
HIGH
LED ON
LED Feedback
During alarm: ON for 3 seconds
During sensitivity adjustment: See Sensitivity Settings
During power-up sequence: See Power-up Sequence
EDGE
JUMPER
SINGLE
DUAL
SINGLE
DUAL
Need help?
Do you have a question about the NV500 and is the answer not in the manual?
Questions and answers