Page 2
CURTIS GOLD CUP BREWER TROUBLESHOOTING GUIDE Model: CGC Service & Sales www.wilburcurtis.com 1-800-421-6150...
Page 4
BREWER PARTS IDENTIFICATION TOP VIEW MAIN VIEW TANK VIEW WATER RELATED HEAT RELATED PART # DESCRIPTION PART # DESCRIPTION 1. WC-1809 FAUCET, HOT WATER 10. WC-589-101 TRANSFORMER, 120/230VAC 2. WC-817 VALVE, DUMP RIGHT 120V 12W 11. WC-6193-0 HEATSINK AND TRIAC 3.
PARTS IMAGES WC-1809 WC-817 WC-889 WC-2962-101K FAUCET, HOT WATER VALVE, DUMP RIGHT VALVE, DUMP LEFT KIT, FITTING SPRAYHEAD WC-29025 WC-826L WC-43062 WC-5527K SPRAYHEAD, PURPLE VALVE, INLET GASKET, TANK LID KIT, PROBE WATER LEVEL O-RING WC-5310 WC-589-101 WC-6193-0 WC-14045-101 TUBE, SILICONE TRANSFORMER HEATSINK AND TRIAC CURRENT SENSOR ASSY G4...
TROUBLESHOOTING INSTRUCTIONS HEATING ISSUES Not heating (120 volt): Not heating (120/220 volt): LCD reads “Heating” LCD reads “Ready” Verify 120 volts between Blu14 & WHT14 Verify that the tank temperature is pro- on the heating element. If yes, replace grammed for 200 degrees. If yes, proceed heating element.
Page 7
TROUBLESHOOTING INSTRUCTIONS TANK FILLING ISSUES Overfilling: Not filling: Turn OFF toggle switch. Yes: Verify 120 volts at the inlet valve coil Does the tank continue to fill? Yes: Replace inlet valve Yes: Replace water inlet valve Remove orange wire from the water Remove the orange wire from the Level probe.
Need help?
Do you have a question about the CGC and is the answer not in the manual?