Smart Laser (CMOS) Amplifier
E3NC-SA0
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
©
OMRON Corporation 2013 All Rights Reserved.
* 5 3 3 8 9 9 4 - 0 B *
PRECAUTIONS ON SAFETY
Meanings of Signal Words
Indicates a potentially hazardous situation which, if not avoided,
WARNING
may result in minor or moderate injury or in property damage.
Warning Indications
WARNING
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR SAFE USE
The following precautions must be observed to ensure safe operation of the product. Doing so may cause
damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
· To secure the safety of operation and maintenance, do not install the product close to high-voltage
devices and power devices.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such
as the ambient temperature and the power supply voltage. Use caution when operating or cleaning the
product.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
PRECAUTIONS FOR CORRECT USE
· Do not miswire such as the polarity of the power supply.
· Be sure to mount the unit to the DIN track until it clicks.
· To prevent electric shock or short circuit, put a protection cap on unused connection power supply
terminals.
Protective Cap
· Do not apply excessive force (9.8N max.) such as tension, compression or torsion to the connector of the
sensor head that is fixed to the amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after
the power is turned on depending on use environment.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work
properly, resulting in malfunction of the unit. In such case, increase the threshold.
· Sensor communication unit E3NW can be used. E3X-DRT21-S and E3X-CRT/ECT cannot be used.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke,
immediately stop using the product, turn off the power, and consult your dealer.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
Checking the Package Content
• Amplifier Unit: 1
• Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)
Compatible Communication Unit (Sold Separately)
E3NW Series Communication Unit, Distribution unit E3NW-DS
1
Installation
Dimensions
1-1
30.2
27.8
13.8
11.5
10
2.6
3.9
5
32.1
9.4
16
49.5
39.5
102.4
DIN Track
OPTICAL COMMUNICATION
SOLD SEPARATELY
PFP-□-N
POSITION
Dimensions in parentheses () indicates the ones with related components.
The cover could come off if it is tilted by 152 degrees or more.
Mounting the Ampli er Unit
1-2
Mounting on DIN Track
(1)
Let the hook on the Amplifier Unit's Sensor Head
  connection side catch the track.
(2)
Push the unit until the hook clicks into place.
Fiber Unit Connection Side Hook
Removing from DIN Track
2
(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while
  performing step (1).
DIN Track
Joining Ampli er Units
(1)
Mount the Amplifier Units one at a time onto the DIN track.
Slide the Amplifier Unit until the communication connector is
closely attached.(Arrow 3)
(2)
Use End Plates (PFP-M: separately sold) at the both
4
ends of the grouped Amplifier Units to prevent them from
separating due to vibration or other cause.(Arrow 4)
(3)
Tighten the screw on the End Plates using a driver.(Arrow 5)
Tighten the screw while pressing the End Plate.
Up to 30 Amplifier Units can be connected to
E3NW Series Communication Unit.
Under environments such as vibration, use an End Plate
even with a single amplifier unit.
Mounting the sensor head
1-3
1.
Open the protection cover.
1
2.
Insert the sensor head, with the lock lever on
its connector area facing upward, all the way
into the connector port.
2
The color of the connector cover for E3NC-SH is white.
Make sure to avoid misconnection by confirming
the cover color in advance.
To remove it, press and hold the lock lever
then pull the sensor head out.
Lock Lever
Connector cover: White
Fix the sensor head with M3 screws.
Apply tightening torque of 0.5N·m for fixing.
・Do not touch the emitter and receiver areas of
the sensor head.
 A fingerprint may prevent proper measurement.
 If you accidentally touch it, use a soft cloth to
wipe it out.
・Fix the connector area so that it should not be
affected by oscillation and impact.
Settings
2
For settings with the Communication Unit,
refer to the User's Manual that comes with the Communication Unit.
Setting and Display Overview
2-1
[L/D Indicator : Orange]
[OUT Selection Indicators:Orange]
Displays Light ON/Dark ON setting.
[ZERO Indicator: Green]
Turns ON when ZERO Rest function is enabled.
[ST Indicator : Blue]
[OUT Indicator:Orange]
Turns ON when Smart Tuning is in progress.
Turns ON when Output is ON.
Measured
Threshold Level
Value
Green Digital Display
White Digital
Sensitivity Setting
Minute Threshold
Mode/OUT Switch
Adjustment
[S.TUNE]
[MODE]Button
Button
[UP/DOWN] Button
Switches between SET mode and RUN mode by a
Performs tuning and [ST Indicator]
The green digital value
long press (3 seconds or longer) of the key. If pressed
turns ON.
changes.
and held for 1 second, OUT is switched.
Smart Tuning [Easy Sensitivity Setting]
2-4
Basic Setting
● 2-point Tuning
Threshold value setting: Set the value in the middle between the measured values for the 1st and 2nd points.
Unit: mm
Workpiece is present
Setting for a workpiece nearer than the background
● 1-point tuning
Threshold value setting: Set the value to the measured value when the button is pressed - usual tolerance.
Workpiece is absent
1
Setting for a Moving Workpiece
● Full Auto Tuning
Threshold value setting: Sets the value to the middle between the maximum and
minimum measured values while the button is being pressed.
3
Hold for 7 seconds or longer
Setting for judging presence/absence of workpiece according to the background
5
● Tuning with workpiece absent
Threshold value setting: Sets the value to the measured value when the button is
pressed and held- usual tolerance.
Workpiece is absent
Setting for sensing within the range of the upper and lower limits
● 2-point area tuning
1. Select [Setting Mode] → [Output1 Mode] → [Area Sensing Mode].
2. Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3. Carry out the same operation as for the 2-point tuning.
Threshold value HIGH: Upper workpiece height + area tolerance
Threshold value LOW: Lower limit workpiece height - area tolerance
The output is inverted at
Sensor
Sensor
Area
the time of Dark-ON.
tolerance
OFF
Threshold Value LOW
ON
Upper limit
Lower limit
Threshold value HIGH
workpiece
workpiece
OFF
Background
Area
(Reference surface)
At the time of
tolerance
Light-ON
Output switching
2-5
■OUT Selection Indicator switches to switch the settings.
1.
Push short the [MODE] button in [Measurement Mode].
2.
OUT Selection Indicators (Output 1/Output 2) switch.
[Output 1]
OUT Selection Indicator (Output 1)
[Output 2]
OUT Selection Indicator (Output 2)
Light-ON/Dark-ON can be switched with output 2. (Refer to 2-2)
Switching Control Output
2-2
Press
button.
L/D
Set to "Light ON" to turn the output ON with a workpiece in the detection area.
+ : Press both
[L/D Indicator] turns
Setting Reset
Set to "Dark ON" to turn ON the output without a sensing object.
L/D
[L/D Indicator] turns
Key Lock
UP/DOWN
MODE
Sensor Head Display
2-3
Zero Reset
UP
Refer to "
Convenient
Setting Features".
Output Switch
Tuning Button
[L/D] Button
Tuning can be executed by holding the
A single press switches between
button as with the [S.Tune] button.
Light ON/Dark ON. [L/D] Indicator
changes.
600
1pnt
Workpiece is absent
Moving the finger off the button displays "2Pnt".
300
1pnt
Hold for 3 seconds or longer
Release the button when "FULL" appears.
The sensor operates only when the area sensing
mode is not selected and background removal is OFF.
100
Workpiece
Turns ON when incident level is insufficient or is saturated at Light-ON.
Turns OFF when incident level is insufficient or is saturated at Dark-ON.
150
150
2pnt
1pnt
Moving the finger off the button displays "2Pnt".
Still hold the button for at least 3 seconds.
Setting for sensing with ± tolerance for workpiece
● 1-point area tuning
1. Select [Setting Mode] → [Output1 Mode] → [Area Sensing Mode].
2. Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3. Carry out the same operation as for the 1-point tuning.
Threshold value HIGH: Upper workpiece height + area tolerance
Threshold value LOW: Lower limit workpiece height - area tolerance
The output is inverted at
the time of Dark-ON.
Area
Sensor
tolerance
Area
OFF
tolerance
Threshold Value LOW
ON
Threshold value HIGH
workpiece
OFF
Background
(Reference surface)
At the time of Light-ON
Margin of the threshold
Margins for threshold are
shown below:
2-4 Smart Tuning
E3NC-SH100 : 8
Normal
E3NC-SH250 : 80
margin
E3NC-SH100 : 4
Area
E3NC-SH250 : 40
margin
Push short the [MODE] button in [Measurement Mode].
Minute Adjustment of Threshold Level
2-6
1.
Press
button to adjust
UP/DOWN
the threshold level.
Hold the key for high-speed level
adjustment.
Workpiece
ON.
Output
ON
for Light-on
OFF
Output
ON
ON.
for Dark-on
OFF
[Tuning Indicator: Blue]
Turns ON when SmartTuning is executed.
[OUT Indicator:Orange]
Turns ON when Output is ON.
[STABILITY Indicator: Green]
Turns ON when output is ON steadily. Specifically, the light
turns ON when workpiece is within the measurement range.
Execution can be done even if the order of workpiece
exists/not exist is reversed.
300
2pnt
Setting is Completed
This setting may be easily influenced by background objects.
290
Setting is Completed
300
Release the button when the workpiece passed through.
Setting is Completed
150
Release the finger when oFFt is displayed.
Setting is Completed
Setting for sensing with ± tolerance for the background
● Area tuning with workpiece absent
1. Select [Setting Mode] → [Output1 Mode] → [Area Sensing Mode].
2. Press and hold the [MODE] button for 3 seconds or longer to exit the Setting Mode.
3. Carry out the same operation as for the tuning with workpiece absent.
Threshold value HIGH: Upper workpiece height + area tolerance
Threshold value LOW: Lower limit workpiece height - area tolerance
The output is inverted at
Area
Sensor
the time of Dark-ON.
Area
tolerance
tolerance
ON
Threshold Value LOW
Background
OFF
(Reference surface)
Threshold value HIGH
ON
At the time of Light-ON
Turns ON when incident level is insufficient or is saturated at Light-ON.
Turns OFF when incident level is insufficient or is saturated at Dark-ON.
Smart Tuning Error
Error Origin
Error / Display / Cause
Remedy
Tuning Type
• Change the response time slower and
Tuning Error
All
then perform tuning again.
• Before tuning, make sure that the
err
e t un
distance between the Sensor and
workpiece is within the measurement
Failed to perform tuning.
range.
• Expand difference in the measured
Near Error
values for the 1st and 2nd points.
2-point Tuning
err
Full Auto Tuning
Difference in the measured
values for the 1st and 2nd
points is too small.
The threshold level
The threshold level
becomes higher.
becomes lower.
E3NC-SA0

Advertisement

loading
Need help?

Need help?

Do you have a question about the E3NC-SA0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omron E3NC-SA0

  • Page 1 + : Press both Displays Light ON/Dark ON setting. [L/D Indicator] turns [ZERO Indicator: Green] 13.8 Thank you for selecting an OMRON product. This sheet Turns ON when ZERO Rest function is enabled. Setting Reset Output 11.5 Set to "Dark ON" to turn ON the output without a sensing object.
  • Page 2 Error output mode: Output is displayed when 6. Output 2 Mode Output mode for the output 2 is changed. Buyer’s application or use of the Product. At Buyer’s request, Omron will Power supply voltage Supplied from the connector through the communications units.