ABB RER620 Product Manual page 41

Advanced recloser protection & control
Hide thumbs Also See for RER620:
Table of Contents

Advertisement

Function name
IEC61850
IEC60617
ANSI/C37.2 Description
Voltage protection
SPHPTOV1
3U >(1)
59-1
SPHPTOV2
3U >(2)
59-2
SPHPTOV3
3U >(3)
59-3
SPHPTUV1
3U <(1)
27-1
SPHPTUV2
3U <(2)
27-2
SPHPTUV3
3U <(3)
27-3
PSPTOV1
U1>(1)
59PS-1
PSPTOV2
U1>(2)
59PS-2
NSPTOV1
U2>(1)
47-1
NSPTOV2
U2>(2)
47-2
ROVPTOV1
Uo>(1)
59N-1
ROVPTOV2
Uo>(2)
59N-2
Total voltage protection functions included
Frequency protection
FRPFRQ1
f</f>,df/dt(1) 81-1
FRPFRQ2
f</f>,df/dt(2) 81-2
LSHDPFRQ1
UFLS/R(1)
81S-1
LSHDPFRQ2
UFLS/R(2)
81S-2
Total frequency protections included
Other protection
PHIZ1
PHIZ1
HIZ
SCCBRBRF1
3I>/Io>BF
50BFT
SCCBRBCF1
SCCBRBCF1
50BFC
DRFLO1
FLO
FLO
DPSRDIR1
P>->
32P
DNZSRDIR1
Q>->
32N
DLCM1
LCM
LCM
Total other protection functions included
Control
SDARREC1
O -> I
79
SECRSYN1
SYNC
25
SCBXCBR1
I<->O CB
52
Total control functions included
Condition monitoring
SPSCBR1
CBCM
52CM
SEQRFUF1
FUSEF
60
Total cond. monitoring functions
Measurements
CMMXU1
3I
IA,IB,IC
CSMTA1
CSMSQI1
I1,I2,I0
I1, I2, I0
RESCMMXU1
Io
IG
VMMXU1
3U
VA,VB,VC
VMMXU2
3U(B)
VA,VB,VC(2) Three-phase voltage measurement, source 2
VSMSQI1
U1,U2,U0
V1,V2,V0
VSMSQI2
U1,U2,U0(B)
V1,V2,V0(2)
APEMMXU1
P,E
P,E
FMMXU1
f
f
Total meas. functions
Three-phase overvoltage 1, source 1 low stage
Three-phase overvoltage 2, source 1 high stage
Three-phase overvoltage 3, source 2 low stage
Three-phase undervoltage 1, source 1 low stage
Three-phase undervoltage 2, source 1 high stage
Three-phase undervoltage 3, source 2 low stage
Positive sequence overvoltage protection, source1
Positive sequence overvoltage protection, source 2
Negative sequence overvoltage protection, source1
Negative sequence overvoltage protection, source 2
Zero sequence overvoltage protection, source1
Zero sequence overvoltage protection, source 2
Underfrequency, overfrequency, frequency rate of change, source
1, stage 1
Underfrequency, overfrequency, frequency rate of change, source
1, stage 2
Load shed & restoration, source 1, stage 1
Load shed & restoration, source 1, stage 2
High Impedance Fault Detector
Circuit breaker failure protection
Circuit breaker close failure protection
Fault Locator (FLOC)
Directional positive sequence power protection
Directional negative/zero sequence power protection
Loop control
Autoreclosing, 1ph and/or 3-ph
Synchro-check/voltage check
Circuit Breaker 1 (3 state inputs / 3 control outputs)
CB condition monitoring
Fuse failure supervision, source 1
Three-phase current
Demand metering, Max/Min metering
Sequence current
Ground current
Three-phase voltage measurement, source 1
Sequence voltage measurement, source 1
Sequence voltage measurement, source 2
Single and three phase power, power factor and three phase
energy, source 1
Frequency measurement, source 1
41
Configuration
RA01 and RA02
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
12
Y
Y
Y
Y
4
Y
Y
Y
Y
Y
Y
Y
7
3
Y
Y
2
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents